Silva R R A, de Freitas P A V, de Oliveira T V, Teixeira S C, Rigolon T C B, Stringheta P C, Otoni C G, Soares N de F F
Department of Food Technology, Federal University of Viçosa, Viçosa, Brazil.
Instituto de Ingeniería de Alimentos para el Desarrollo, Universidad Politécnica de Valencia, Valencia, Spain.
Int J Biol Macromol. 2024 Oct;277(Pt 4):134486. doi: 10.1016/j.ijbiomac.2024.134486. Epub 2024 Aug 3.
Food from animal sources (e.g., fish) represents the food group most likely to disseminate diseases to humans. To prevent food contamination and foodborne illnesses, intelligent packaging has been developed to monitor fish freshness by real-time tracking their physicochemical attributes and informing consumers about their conservation state. In this context, we investigated the influence of ionic strength (IS) provided by CaCl on the chromatic response of anthocyanin açai extracts incorporated into methylcellulose (MC) within hydrocolloid-based colorimetric sensors for monitoring the freshness of Lambari fish. The color sensitivity of the sensors was modulated by IS in the presence of NH volatile and/or TVB-N. Increasing IS led to a plasticizing effect in the MC matrix, which influenced the chromatic properties of anthocyanin in the presence of NH and/or TVB-N. The perception of distinct colors by untrained eyes improved from 10 min with the control sensor to 2.5 min for sensors with IS >50 mM. Adjusting the IS to 500 mM with LiCl, CaCl, or MgCl resulted in gray-green, blue, or moss-green colors, respectively, diverging from the control sensor's color (pink and gray) after 10 min of ammonia exposure, confirming salt-induced copigmentation. Color irreversibility in the sensors was achieved when the IS exceeded 250 mM. Through principal component analysis, we statistically validate the efficacy of the sensor in assessing the freshness of Lambari fish. The sensor maintained its color-change capability even after 60 d of storage and was able to classify Lambari fish freshness according to Brazilian and European standards. This study elucidates the interrelation between the structures and properties of natural compounds such as MC, anthocyanin, and CaCl, providing a method to control the chromatic properties of sensors intended to monitor food quality, safety, and shelf-life.
来自动物源的食物(如鱼类)是最有可能将疾病传播给人类的食物类别。为防止食物污染和食源性疾病,已开发出智能包装,通过实时跟踪鱼类的物理化学属性并向消费者告知其保存状态来监测鱼的新鲜度。在此背景下,我们研究了氯化钙提供的离子强度(IS)对基于水胶体的比色传感器中掺入甲基纤维素(MC)的巴西莓花青素提取物的色度响应的影响,该传感器用于监测兰巴里鱼的新鲜度。在存在挥发性氨和/或TVB - N的情况下,传感器的颜色敏感性受IS调节。增加IS会导致MC基质产生增塑作用,这在存在氨和/或TVB - N的情况下影响花青素的色度特性。未经训练的眼睛对不同颜色的辨别时间从使用对照传感器的10分钟缩短至IS>50 mM的传感器的2.5分钟。用氯化锂、氯化钙或氯化镁将IS调整到500 mM时,分别产生灰绿色、蓝色或苔绿色,在氨气暴露10分钟后与对照传感器的颜色(粉红色和灰色)不同,证实了盐诱导的共色素作用。当IS超过250 mM时,传感器实现了颜色不可逆性。通过主成分分析,我们从统计学上验证了该传感器在评估兰巴里鱼新鲜度方面的有效性。该传感器即使在储存60天后仍保持其变色能力,并能够根据巴西和欧洲标准对兰巴里鱼的新鲜度进行分类。本研究阐明了MC、花青素和氯化钙等天然化合物的结构与性质之间的相互关系,提供了一种控制旨在监测食品质量、安全和保质期的传感器色度特性的方法。