Suppr超能文献

超声引导下经股浅静脉置入中心静脉导管于肾静脉的罕见异位:一例报告

Uncommon Malposition of an Ultrasound-Guided Central Venous Catheter in the Renal Vein through the Superficial Femoral Vein: A Case Report.

作者信息

Young Ting-Chia Remus, Cheng Kuang-Hua, Yu Kuan-Pen

机构信息

Department of Critical Care Medicine, MacKay Memorial Hospital, Taipei, Taiwan.

Department of Medicine, Mackay Medical College, New Taipei, Taiwan.

出版信息

J Crit Care Med (Targu Mures). 2024 Jul 31;10(3):266-270. doi: 10.2478/jccm-2024-0026. eCollection 2024 Jul.

Abstract

INTRODUCTION

Malposition is a relatively rare complication associated with peripherally inserted central catheters (PICCs), particularly in cases of superficial femoral vein (SFV) catheterization. To the best of our knowledge, we are the first to report this rare case of SFV PICC malposition in the contralateral renal vein.

CASE PRESENTATION

An 82-year-old woman underwent bedside cannulation of the SFV for PICC under ultrasound guidance. Subsequent radiographic examination revealed an unexpected misplacement, with the catheter tip positioned toward the contralateral renal vein. After pulling out the catheter on the basis of the X-ray result, it was observed that the catheter retained its function.

CONCLUSION

Although rare, tip misplacement should be considered in SFV PICC placement. Prompt correction of the tip position is crucial to prevent catheter malfunction and further catastrophic consequences. For critical patients receiving bedside SFV PICC insertion, postoperational X-ray is crucial for enhancing safety.

摘要

引言

导管位置异常是外周静脉穿刺中心静脉导管(PICC)相对少见的并发症,尤其是在股浅静脉(SFV)置管时。据我们所知,我们首次报道了这例罕见的SFV PICC导管异位至对侧肾静脉的病例。

病例介绍

一名82岁女性在超声引导下于床边行SFV的PICC置管。随后的影像学检查发现意外的导管位置不当,导管尖端朝向对侧肾静脉。根据X线结果拔出导管后,发现导管仍能发挥功能。

结论

尽管少见,但在SFV PICC置管时应考虑导管尖端位置异常。及时纠正尖端位置对于预防导管故障和进一步的灾难性后果至关重要。对于接受床边SFV PICC置管的重症患者,术后X线检查对于提高安全性至关重要。