Levien L J, Voll C L, Lithgow-Jolly P, Fritz V U
Stroke. 1985 Nov-Dec;16(6):945-9. doi: 10.1161/01.str.16.6.945.
A battery of simple noninvasive tests consisting of directional Doppler ultrasound and carotid phonoangiography has been used to detect carotid stenosis in 700 patients Forty four carotid occlusions in 42 patients were confirmed on angiography, and this study examines the accuracy of this noninvasive battery in predicting the presence of an occluded internal carotid artery. Although the sensitivity of the battery described has been 70% for occlusion, with a specificity of 98% (only five false positives), this relatively low sensitivity and the uniform requirement for surgery in the false positive group have led us to conclude that this battery should not be used as a substitute for angiography when the diagnosis of internal carotid occlusion requires to be confirmed. Nevertheless, these noninvasive tests do have a role in alerting the physician to the presence of carotid occlusion and contralateral carotid artery stenosis, allowing more specific planning of any subsequent arteriography required.
一组由定向多普勒超声和颈动脉血管音造影组成的简单无创检查已被用于检测700例患者的颈动脉狭窄。42例患者的44处颈动脉闭塞经血管造影得到证实,本研究检验了这一无创检查组合预测颈内动脉闭塞存在情况的准确性。尽管所描述的检查组合对闭塞的敏感性为70%,特异性为98%(仅有5例假阳性),但这种相对较低的敏感性以及对假阳性组统一的手术要求使我们得出结论,当需要确诊颈内动脉闭塞时,不应将该检查组合用作血管造影的替代方法。然而,这些无创检查在提醒医生注意颈动脉闭塞和对侧颈动脉狭窄的存在方面确实有作用,从而可以更具体地规划随后所需的任何血管造影检查。