Weissbach A, Freymann E, Hubl W, Seefried W, Neef B, Thiele H J
Exp Clin Endocrinol. 1985 Dec;86(2):178-84. doi: 10.1055/s-0029-1210484.
An enzymeimmunoassay (EIA) for unconjugated estriol was developed. Estriol-6-CMO-BSA was used as antigen for the antiserum production with low cross reactivities to estrone (0.3%) and estradiol (0.17%). The enzyme conjugate (estriol-peroxidase) was prepared using the mixed anhydride reaction. The antibody bound estriol fraction was separated from the free fraction with the double antibody technique. The test requires a simple photometer for the measurement of enzyme label. The developed estriol-EIA needs a short incubation time (2 hrs). The normal values of estriol in serum were determined. The results are in good agreement with the results of RIA. Furthermore, we found an inverse diurnal rhythm of serum and salivary estriol in comparison to the cortisol level. Low estriol levels in the morning and high estriol concentration in the evening are indices of fetal health. Decreased estriol levels in the morning of several days were found in pathological pregnancies (intrauterine fetal death, fetal distress, hepatose).
开发了一种用于检测未结合雌三醇的酶免疫测定法(EIA)。雌三醇-6-羧甲基肟-牛血清白蛋白(Estriol-6-CMO-BSA)被用作抗原以产生抗血清,该抗血清与雌酮(0.3%)和雌二醇(0.17%)的交叉反应性较低。使用混合酸酐反应制备酶结合物(雌三醇-过氧化物酶)。采用双抗体技术将抗体结合的雌三醇部分与游离部分分离。该检测需要一台简单的光度计来测量酶标记物。所开发的雌三醇EIA需要较短的孵育时间(2小时)。测定了血清中雌三醇的正常值。结果与放射免疫测定法(RIA)的结果高度一致。此外,与皮质醇水平相比,我们发现血清和唾液中雌三醇存在昼夜节律倒置现象。早晨雌三醇水平低而晚上雌三醇浓度高是胎儿健康的指标。在病理妊娠(宫内胎儿死亡、胎儿窘迫、肝炎)中发现数天早晨雌三醇水平降低。