Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, UK.
Int J Hyperthermia. 2024;41(1):2389292. doi: 10.1080/02656736.2024.2389292. Epub 2024 Aug 12.
High intensity focused ultrasound (HIFU) can destroy tissue by thermal ablation which may be accompanied by acoustic cavitation and/or tissue water boiling, but the biological and histological effects of these treatments have not been fully documented. Here, detailed histological analysis over time using well characterized HIFU exposures in rat livers is described. Exposures used invoked either (i) thermal, with acoustic cavitation and/or tissue water boiling or (ii) predominantly thermal damage. Cavitation activity was detected using both active and passive methods. Histological assessment involved hematoxylin and eosin (H&E), picrosirius red and immunohistochemical staining. Distinct concentric damage regions were identified after HIFU exposures. The outermost ring showed a red H&E-stained rim that was characterized by hemorrhage. The adjacent inner band appeared white due to increased extracellular spaces. The morphology of the next zone depended on the exposure. Where there was no tissue acoustic cavitation/water boiling, this was the lesion center, in which heat-fixed cells were seen. Where acoustic cavitation/boiling occurred, a centermost zone with irregular holes up to several hundred microns across was seen. Cleaved caspase-3 and Hsp70 staining in the periphery of both types of HIFU exposures was seen within the outermost ring of hemorrhage, where an inflammatory response was also observed. By day 7, a distinct acellular region in the center of the HIFU lesions had been created. These results identify the morphological effects and elucidate the similarities and differences of HIFU-induced thermal lesions in the presence or absence of acoustic cavitation/tissue water boiling.
高强度聚焦超声(HIFU)可以通过热消融破坏组织,这可能伴随着声空化和/或组织水沸腾,但这些治疗的生物学和组织学效应尚未得到充分记录。在这里,描述了在大鼠肝脏中使用经过良好表征的 HIFU 暴露进行的随时间变化的详细组织学分析。使用的暴露要么引起(i)热,伴有声空化和/或组织水沸腾,要么引起(ii)主要的热损伤。使用主动和被动方法检测空化活性。组织学评估涉及苏木精和伊红(H&E)、苦味酸天狼星红和免疫组织化学染色。在 HIFU 暴露后,可识别出明显的同心损伤区域。最外层的环显示出红色的 H&E 染色边缘,其特征是出血。相邻的内层带由于细胞外空间增加而呈现白色。下一个区域的形态取决于暴露。在没有组织声空化/水沸腾的情况下,这是病变中心,其中可以看到热固定的细胞。在发生声空化/沸腾的情况下,可以看到一个中心区,其中有直径达数百微米的不规则孔。在两种类型的 HIFU 暴露的外围都可以看到 cleaved caspase-3 和 Hsp70 染色,在外周出血的最外层环中也观察到炎症反应。在第 7 天,HIFU 病变的中心形成了一个明显的无细胞区。这些结果确定了形态学效应,并阐明了存在或不存在声空化/组织水沸腾时 HIFU 诱导的热损伤的相似性和差异。