Suppr超能文献

V4c可植入式胶原晶状体植入术的十年临床结果:视力、内皮细胞密度和房拱动态的纵向分析

Ten-Year Clinical Outcomes of V4c Implantable Collamer Lens Implantation: Longitudinal Analysis of Visual Acuity, Endothelial Cell Density, and Vault Dynamics.

作者信息

Chung Byunghoon, Choi Jin Young, Kang David S Y, Kim Kangyoon, Kim Bo Yi, Kim Tae-Im

机构信息

From the Eyereum Eye Clinic (B.C., J.Y.C., D.S.Y.K., K.Y.K.), Seoul, Republic of Korea.

Corneal Dystrophy Research Institute, Department of Ophthalmology (B.Y.K., T.K.), Yonsei University College of Medicine, Seoul, Republic of Korea.

出版信息

Am J Ophthalmol. 2025 Jan;269:1-10. doi: 10.1016/j.ajo.2024.08.007. Epub 2024 Aug 13.

Abstract

PURPOSE

This study aimed to evaluate the long-term clinical outcomes of V4c Implantable Collamer Lens (ICL) implantation for myopia correction over a 10-year period.

DESIGN

Retrospective interventional case series METHODS: This retrospective interventional study involved 103 myopic eyes from 54 patients. Visual outcomes, including visual acuity and manifest refraction were assessed. Annual measurements of endothelial cell density (ECD), vault, anterior chamber depth, and intraocular pressure were analyzed using mixed-effects models.

RESULTS

At the 10-year follow-up, the mean Logarithm of the Minimum Angle of Resolution (logMAR) uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were -0.037 ± 0.052 and -0.041 ± 0.046, respectively. The mean efficacy and safety indices were 1.11 ± 0.13 and 1.12 ± 0.12. A loss of one line of CDVA occurred in 2% of cases, while 59% gained one or more lines. Postoperative manifest refraction spherical equivalent (MRSE) was within ±0.5 diopters (D) and ±1.0 D in 74% and 99% of cases, respectively, with a mean MRSE of -0.19 ± 0.41 D. Data for ECD and vault fit an exponential decay model, demonstrating a continuous yet gradually slowing decrease over time. Decay rates were 0.012 ± 0.001 per year for ECD and 0.056 ± 0.003 per year for the vault. Notably, ECD lower outliers had significantly lower preoperative ECD values. There were no instances of cataract formation, angle closure, glaucoma, or ICL removal throughout the study.

CONCLUSIONS

The 10-year outcomes of V4c ICL implantation demonstrate effective and safe visual results. Both ECD and vault exhibit exponential decay patterns over the decade. Patients with lower preoperative ECD values require careful post-implantation monitoring.

摘要

目的

本研究旨在评估V4c可植入式胶原晶状体(ICL)植入术在10年期间矫正近视的长期临床效果。

设计

回顾性干预病例系列

方法

本回顾性干预研究纳入了54例患者的103只近视眼睛。评估了包括视力和显验光在内的视觉结果。使用混合效应模型分析每年测量的内皮细胞密度(ECD)、前房深度、房拱高度和眼压。

结果

在10年随访时,平均最小分辨角对数(logMAR)未矫正远视力和矫正远视力(CDVA)分别为-0.037±0.052和-0.041±0.046。平均有效性和安全性指数分别为1.11±0.13和1.12±0.12。2%的病例CDVA下降了一行,而59%的病例提高了一行或多行。术后显验光球镜等效度(MRSE)在±0.5屈光度(D)和±1.0 D范围内的病例分别为74%和99%,平均MRSE为-0.19±0.41 D。ECD和房拱高度的数据符合指数衰减模型,表明随着时间的推移持续但逐渐减缓下降。ECD的衰减率为每年0.012±0.001,房拱高度的衰减率为每年0.056±0.003。值得注意的是,ECD较低的异常值术前ECD值明显较低。在整个研究过程中,没有出现白内障形成、房角关闭、青光眼或ICL取出的情况。

结论

V4c ICL植入术的10年结果显示出有效且安全的视觉效果。在这十年中,ECD和房拱高度均呈现指数衰减模式。术前ECD值较低的患者术后需要仔细监测。