Department of Ophthalmology, Affiliated Hospital of Nanjing University of TCM, Shanghai Road, Nanjing, 210029, China.
Nanjing University of Chinese Medicine, 138 Xianlin Rd, Nanjing, China.
BMC Ophthalmol. 2024 Aug 19;24(1):351. doi: 10.1186/s12886-024-03624-1.
To investigate the repeatability and reproducibility of a new method for centration analysis after small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK (FS-LASIK).
This study comprised 29 eyes treated with SMILE and 24 with FS-LASIK. Decentrations were analyzed using tangential and pachymetry difference maps respectively. Both difference maps were generated with a Scheimpflug tomographer (Pentacam) for each eye, using preoperative and 3-month postoperative scans. Repeatability and reproducibility were evaluated by calculating the intraclass correlation coefficient (ICC), within-subject standard deviation (Sw), and coefficient of repeatability (CR).
ICC, Sw, and CR showed good to excellent repeatability in locating the coordinates of the optical zone (OZ) center on both maps, with values ranging from 0.84 to 0.96, 0.03 to 0.13, and 0.08 to 0.36 respectively. The repeatability of the total decentration from the preoperative corneal vertex on the tangential curvature difference maps( ) and the pachymetry difference maps( ) were moderate and good, respectively. The ICC, Sw, and CR of were 0.63, 0.09, and 0.25, respectively. The ICC, Sw, and CR of were 0.77, 0.10, and 0.28, respectively. The reproducibility of the OZ center measurements was excellent for the tangential difference maps (ICC ) and good for the pachymetry difference maps (ICC 0.86). ICC, Sw, and CR showed excellent reproducibility of , with values of 0.95, 0.03, and 0.08, respectively. ICC, Sw, and CR showed good reproducibility of , with values of 0.89, 0.06, and 0.17, respectively.
The centration analysis method used in this study showed good to excellent repeatability and reproducibility in locating the coordinates of the center of the OZ on the tangential and pachymetry difference maps.
研究一种新的小切口微透镜提取(SMILE)和飞秒激光辅助 LASIK(FS-LASIK)后准心分析的重复性和可再现性。
本研究纳入 29 例 SMILE 治疗眼和 24 例 FS-LASIK 治疗眼。分别使用切线和角膜厚度差图分析离焦。使用 Pentacam Scheimpflug 断层扫描仪对每只眼的术前和术后 3 个月的扫描图像分别生成这两种差图。通过计算组内相关系数(ICC)、个体内标准差(Sw)和可重复性系数(CR)来评估重复性和可再现性。
ICC、Sw 和 CR 显示在两种差图上定位光区(OZ)中心坐标的重复性均较好至极好,范围分别为 0.84 至 0.96、0.03 至 0.13 和 0.08 至 0.36。术前角膜顶点在切线曲率差图( )和角膜厚度差图( )上的总离焦的重复性为中等和良好,ICC、Sw 和 CR 分别为 0.63、0.09 和 0.25,0.77、0.10 和 0.28。OZ 中心测量的可重复性在切线差图上极好(ICC ),在角膜厚度差图上良好(ICC )。 的 ICC、Sw 和 CR 分别为 0.95、0.03 和 0.08, 的 ICC、Sw 和 CR 分别为 0.89、0.06 和 0.17。
本研究使用的准心分析方法在定位 OZ 中心的切线和角膜厚度差图上的坐标时,具有较好至极好的重复性和可再现性。