Suppr超能文献

Mitris RESILIA 瓣膜:成熟设计的全新“外衣”。

The Mitris RESILIA Valve: New Skin for a Proven Design.

机构信息

Cardiac Surgery Division, University of Padua, Padua, Italy.

Cardiac Surgery Division, European Hospital, Rome, Italy.

出版信息

Surg Technol Int. 2024 Jul 15;44:197-201. doi: 10.52198/24.STI.44.CV1792.

Abstract

By incorporating the best features of the Carpentier-Edwards PERIMOUNT Magna Mitral Ease valve (Edwards Lifesciences Corporation, Irvine, California) and INSPIRIS RESILIA tissue (Edwards Lifesciences Corporation, Irvine, California), the mitris valve inherits the advantages of the remarkable hemodynamic performance of the former and the durability of the latter. In this paper, we will summarize the process that led to the creation of this new valve and report on the first implant's feasibility and first impression. The mitris valve has an overall implantability profile, overlapping the previous generation with no added challenges, but compared to the PERIMOUNT Magna Mitral Ease valve, the mitris valve boasts a more pliable saddle-shaped sewing cuff that is specifically tailored to fit the complex structure of the mitral valve with a lower stent height. This could be particularly beneficial in the context of double-valve replacement, as it may prevent any disturbance to the bioprosthesis located in the aortic position in small annulus. This could also prevent some rare but unpleasant complications such as left ventricle outflow obstruction or rupture of the atrioventricular sulcus. In addition, it could allow for better adherence to the saddle-shaped annulus of the mitral valve with the possibility of less stress (and therefore fibrosis) on the valve tissue, while further reducing the degeneration time. Furthermore, thanks to the possibility of being temporarily adjusted inwards, it is possible to ensure greater implantability compared to the previous generation of Magna Edwards mitral valves. Thanks to INSPIRIS technology, which prevents the generation of free aldehydes that promote oxidation and calcification of pericardial tissue, it is possible to assume that the durability will probably also improve. This reinforces the trustworthiness of the mitris valve.

摘要

通过融合 Carpentier-Edwards PERIMOUNT Magna 二尖瓣 Ease 瓣膜(爱德华生命科学公司,加利福尼亚州欧文)和 INSPIRIS RESILIA 组织(爱德华生命科学公司,加利福尼亚州欧文)的最佳特性,mitris 瓣膜继承了前者卓越的血液动力学性能和后者耐久性的优点。在本文中,我们将总结导致创建这种新型瓣膜的过程,并报告首例植入的可行性和初步印象。mitris 瓣膜具有整体可植入性,与上一代重叠,没有增加任何挑战,但与 PERIMOUNT Magna 二尖瓣 Ease 瓣膜相比,mitris 瓣膜具有更柔韧的鞍形缝合袖口,专门设计用于适应二尖瓣的复杂结构,支架高度更低。这在双瓣置换的情况下可能特别有益,因为它可能防止位于小瓣环主动脉位置的生物假体受到任何干扰。这也可以防止一些罕见但不愉快的并发症,如左心室流出道梗阻或房室沟破裂。此外,它可以允许更好地贴合二尖瓣的鞍形瓣环,并且可能减少瓣膜组织上的压力(因此纤维化),同时进一步缩短退变时间。此外,由于可以临时向内调整,因此与前代 Magna Edwards 二尖瓣相比,可能具有更大的可植入性。由于 INSPIRIS 技术可防止产生促进心包组织氧化和钙化的游离醛,因此可以假设耐久性也可能得到改善。这增强了 mitris 瓣膜的可信度。

相似文献

2
Implantability of the MITRIS RESILIA Mitral Valve.MITRIS RESILIA 二尖瓣的可植入性。
Ann Thorac Surg. 2022 Apr;113(4):e295-e297. doi: 10.1016/j.athoracsur.2021.05.065. Epub 2021 Jun 17.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验