Ikutomo Hisashi, Nakamura Masatoshi, Okamura Kenichi, Togomori Keiichi, Nakagawa Norikazu, Masuhara Kensaku
Department of Rehabilitation, Masuhara Clinic, Osaka, Japan.
Faculty of Rehabilitation Sciences, Nishikyusyu University, Saga, Japan.
J Orthop Sci. 2025 May;30(3):499-506. doi: 10.1016/j.jos.2024.08.003. Epub 2024 Sep 2.
A vibration roller is an effective tool for reducing muscle soreness and improving damaged muscle function. However, its efficacy in reducing hip pain and improving function after total hip arthroplasty is unclear. We investigated the effect of lower limb vibration using a vibration roller on postoperative hip pain and function after total hip arthroplasty in a randomized controlled clinical trial.
Thirty patients scheduled for total hip arthroplasty were randomly assigned to vibration and control groups. The patients in the vibration group performed lower limb vibration using a vibration roller. The patients in the control group performed sham therapy using a hot pack. Patients performed both interventions for 10 min daily on postoperative days 1-7, in addition to regular physical therapy. Primary outcome was hip pain intensity as measured using a visual analog scale. Secondary outcomes were pain-pressure threshold and serum creatine kinase and C-reactive protein levels. We also assessed physical functions, including the Harris Hip Score, range of motion of the hip joint, muscle strength, gait velocity, and timed up-and-go test. The effects of the interventions on outcome measurements in the groups were compared using a split-plot design variance analysis.
After one week of the intervention and three weeks of follow-up, the vibration group showed statistically significant improvement in the exercise-induced hip pain, pain-pressure threshold of lateral thigh, and serum creatine kinase compared to the control group (p = 0.006, 0.003, and 0.012, respectively). No statistically significant differences were found between the groups regarding the physical functions.
Lower limb vibration using a vibration roller after total hip arthroplasty was an effective intervention to reduce exercise-induced hip pain and improve serum creatine kinase, but there was no synergistic effect on the physical functions.
振动滚筒是减轻肌肉酸痛和改善受损肌肉功能的有效工具。然而,其在全髋关节置换术后减轻髋关节疼痛和改善功能方面的疗效尚不清楚。我们在一项随机对照临床试验中研究了使用振动滚筒进行下肢振动对全髋关节置换术后髋关节疼痛和功能的影响。
30例计划进行全髋关节置换术的患者被随机分为振动组和对照组。振动组患者使用振动滚筒进行下肢振动。对照组患者使用热敷袋进行假治疗。除常规物理治疗外,患者在术后第1至7天每天进行两种干预,各10分钟。主要结局是使用视觉模拟量表测量的髋关节疼痛强度。次要结局是疼痛压力阈值、血清肌酸激酶和C反应蛋白水平。我们还评估了身体功能,包括Harris髋关节评分、髋关节活动范围、肌肉力量、步态速度和计时起立行走测试。使用裂区设计方差分析比较两组干预对结局测量的影响。
干预1周和随访3周后,与对照组相比,振动组在运动诱发的髋关节疼痛、大腿外侧疼痛压力阈值和血清肌酸激酶方面有统计学显著改善(分别为p = 0.006、0.003和0.012)。两组在身体功能方面未发现统计学显著差异。
全髋关节置换术后使用振动滚筒进行下肢振动是减轻运动诱发的髋关节疼痛和改善血清肌酸激酶的有效干预措施,但对身体功能没有协同作用。