Suppr超能文献

促黄体生成激素释放激素类似物[D-丝氨酸(叔丁基)]6去甘氨酰胺(10)乙酰胺(布舍瑞林)的放射免疫分析

Radioimmunoassay of an analog of luteinizing hormone-releasing hormone, [D-Ser(tBu)]6des-Gly-NH2(10) ethylamide (Buserelin).

作者信息

Saito S, Saito H, Yamasaki R, Hosoi E, Komatsu M, Iwahana H, Maeda T

出版信息

J Immunol Methods. 1985 May 23;79(2):173-83. doi: 10.1016/0022-1759(85)90097-3.

Abstract

A sensitive and specific radioimmunoassay is described for plasma and urinary levels of [D-Ser(tBu)]6des-Gly-NH2(10) ethylamide (buserelin). No appreciable cross-reaction (less than 0.05%) was observed with LH-RH and its analogs other than buserelin fragments (1.6-45%). The sensitivity was 3 pg per tube. At buserelin concentrations of 125, 250 and 500 pg/ml, the intra- and inter-assay coefficients of variation were 7.9, 10.0 and 10.0%, and 19.0, 7.8 and 6.8% respectively. Recovery of buserelin added to plasma was quantitative (62.5 pg/ml, 101.6%; 125 pg/ml, 76.8% and 250 pg/ml, 63.4%). A dose of 5 micrograms buserelin injected subcutaneously into 5 normal male adults, reached a peak plasma level in 45 min (mean value 119.3 +/- 47.3 pg/ml) and remained detectable for at least 4 h. The half disappearance time was 118.8 +/- 26.0 min. Between 9 and 16% of the administered dose was excreted in the urine within 24 h. Buserelin could also be detected in the plasma after intranasal administration of doses of 150, 300 and 450 micrograms. There was a significant difference in the area under the curve (AUC) for plasma levels after subcutaneous injection of 5 micrograms and intranasal administration of 150 micrograms, but not between the AUC values after the three intranasal doses. These results indicate that this method for radioimmunoassay of buserelin is suitable for analyzing the pharmacokinetics and bioavailability of buserelin in man.

摘要

本文描述了一种用于检测血浆和尿液中[D-丝氨酸(叔丁基)]6去甘氨酰胺(10)乙酰胺(布舍瑞林)水平的灵敏且特异的放射免疫分析法。除布舍瑞林片段(1.6 - 45%)外,未观察到与促黄体生成素释放激素(LH-RH)及其类似物有明显交叉反应(小于0.05%)。灵敏度为每管3皮克。在布舍瑞林浓度为125、250和500皮克/毫升时,批内和批间变异系数分别为7.9%、10.0%和10.0%,以及19.0%、7.8%和6.8%。添加到血浆中的布舍瑞林回收率是定量的(62.5皮克/毫升,回收率101.6%;125皮克/毫升,76.8%;250皮克/毫升,63.4%)。给5名正常成年男性皮下注射5微克布舍瑞林,45分钟时达到血浆峰值水平(平均值119.3±47.3皮克/毫升),至少4小时内仍可检测到。半衰期为118.8±26.0分钟。给药剂量的9%至16%在24小时内随尿液排出。经鼻给予150、300和450微克剂量后,血浆中也能检测到布舍瑞林。皮下注射5微克和经鼻给予150微克后血浆水平曲线下面积(AUC)有显著差异,但三种经鼻给药剂量后的AUC值之间无差异。这些结果表明,这种布舍瑞林放射免疫分析方法适用于分析布舍瑞林在人体中的药代动力学和生物利用度。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验