Abstract

Expansion Microscopy (ExM) is an innovative and cost-effective super-resolution microscopy technique that has become popular in cell biology research. It achieves super-resolution by physically expanding specimens. Since its introduction, ExM has undergone continuous methodological developments to enhance its resolution and labeling capabilities. However, ExM imaging often encounters sample drift during image acquisition due to the physical movement of the expanded hydrogel, posing a significant challenge for accurate image reconstruction. Despite many proposed experimental solutions to mitigate sample drift, a universal solution has yet to be established. In response to this challenge, we developed 3D-Aligner, an advanced and user-friendly image analysis tool designed to computationally correct drift in ExM images for precise three-dimensional image reconstruction and downstream quantification. We demonstrate that 3D-Aligner effectively determines and corrects drift in ExM images with different expansion rates and various fluorescently labeled biological targets, showcasing its capabilities and robustness in drift correction. Additionally, we validate the precision of 3D-Aligner by comparing drift values across different labeled targets and highlight the importance of drift correction in quantification of biological structures.

摘要

扩展显微镜技术(ExM)是一种创新且经济高效的超分辨率显微镜技术,已在细胞生物学研究中广泛应用。它通过物理方式扩展样本实现超分辨率。自问世以来,ExM在方法学上不断发展,以提高其分辨率和标记能力。然而,在图像采集过程中,由于膨胀水凝胶的物理移动,ExM成像经常会出现样本漂移,这给精确的图像重建带来了重大挑战。尽管已经提出了许多实验性解决方案来减轻样本漂移,但尚未找到通用的解决方案。针对这一挑战,我们开发了3D - Aligner,这是一种先进且用户友好的图像分析工具,旨在通过计算校正ExM图像中的漂移,以实现精确的三维图像重建和下游定量分析。我们证明,3D - Aligner能够有效地确定并校正不同膨胀率以及各种荧光标记生物靶点的ExM图像中的漂移,展示了其在漂移校正方面的能力和稳健性。此外,我们通过比较不同标记靶点的漂移值来验证3D - Aligner的精度,并强调了漂移校正在生物结构定量分析中的重要性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/f865/11384005/7037df2a0b7f/nihpp-2024.08.28.610199v1-f0001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验