超声对离体肠道模型中不同摄入性异物的成像研究。

Ultrasound Imaging of Various Ingested Foreign Bodies in an Ex Vivo Intestinal Model.

机构信息

From the University of California, Davis-School of Medicine, Sacramento, CA.

University of California, Davis, Davis, CA.

出版信息

Pediatr Emerg Care. 2024 Dec 1;40(12):850-855. doi: 10.1097/PEC.0000000000003269. Epub 2024 Sep 12.

Abstract

OBJECTIVE

Foreign body ingestion is an increasingly prevalent issue for children who are in the preverbal to early verbal stages of life. Foreign bodies lodged in the gastrointestinal tract can cause issues such as obstruction, perforation, and fistulae. Radiographic imaging can often locate most foreign bodies; however, radiolucent objects may be missed. Ultrasound is an alternative imaging modality that can be used to locate and track foreign objects as they pass through the bowel. The objective of this study was to characterize the sonographic appearance of various ingested foreign bodies of varying characteristics in an ex vivo gastrointestinal tract segment.

METHODS

A GE Logiq 9 ultrasound machine with a linear transducer at a frequency of 15 MHz was used to examine various ingested foreign bodies placed in a segment of pig intestinal tract.

RESULTS

Imaged objects varied in visual appearance from echogenicity, texture, size, and shape; acoustic shadows and reverberation artifacts cast were particularly distinguishing characteristics.

CONCLUSIONS

Ultrasound evaluation to assess foreign body ingestion in the pediatric population may provide a useful alternative or supportive imaging modality in confirming the location and real-time tracking of the ingested item. This may be especially useful for objects of varying radiodensities that cannot always be reliably seen in traditional radiographs.

摘要

目的

对于处于言语前期到早期言语阶段的儿童,异物摄入是一个日益普遍的问题。胃肠道内的异物会导致梗阻、穿孔和瘘管等问题。放射影像学检查通常可以定位大多数异物;然而,不透射线的物体可能会被遗漏。超声是一种替代的成像方式,可用于定位和跟踪通过肠道的异物。本研究的目的是描述在离体胃肠道段中各种不同特征的摄入性异物的超声表现。

方法

使用频率为 15MHz 的 GE Logiq 9 超声机和线性换能器检查放置在猪肠段中的各种摄入性异物。

结果

成像物体的可视外观在回声特性、质地、大小和形状上存在差异;声影和混响伪影是特别具有鉴别特征的。

结论

在儿科人群中,超声评估用于评估异物摄入可能提供了一种有用的替代或辅助成像方式,可用于确认摄入物的位置和实时跟踪。对于传统 X 光片无法可靠显示的不同密度的物体,这可能特别有用。

相似文献

4
[Ultrasound imaging of foreign bodies--an experimental study].[异物的超声成像——一项实验研究]
Biomed Tech (Berl). 1996 Nov;41(11):308-15. doi: 10.1515/bmte.1996.41.11.308.
9
Sonographic features of various dental materials and foreign bodies.各种牙科材料和异物的超声表现。
Dentomaxillofac Radiol. 2022 Feb 1;51(2):20210182. doi: 10.1259/dmfr.20210182. Epub 2021 Aug 4.
10
Foreign body ingestion in children.儿童误吞异物
Am Fam Physician. 2005 Jul 15;72(2):287-91.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验