Suppr超能文献

伊普斯威奇触觉测试在识别糖尿病患者保护性感觉丧失方面的准确性和可靠性。

Accuracy and reliability of the Ipswich touch test in identifying loss of protective sensation among diabetic patients.

作者信息

Khumchum Napassorn, Koonalinthip Nantawan, Janchai Siriporn

机构信息

Department of Rehabilitation Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.

Department of Rehabilitation Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.

出版信息

Foot (Edinb). 2024 Dec;61:102132. doi: 10.1016/j.foot.2024.102132. Epub 2024 Sep 11.

Abstract

OBJECTIVE

To evaluate the accuracy of the Ipswich touch test compared to the 10-g monofilament test for identifying of loss of protective sensation in Thai patients with diabetes mellitus.

METHODS

A cross-sectional observational study was conducted on Thai patients with diabetes mellitus who attended routine annual foot check-ups in an outpatient diabetes clinic. The loss of protective sensation was assessed by the Ipswich touch test and compared with the Semmes-Weinstein 10-g monofilament test. Sensitivity, specificity, predictive values and likelihood ratios were calculated to measure the accuracy of the Ipswich touch test against 10-g monofilament as a reference standard. The interrater reliability of the Ipswich touch test was assessed by two raters.

RESULTS

In a study of 283 diabetic patients, 10-g monofilament detected a 25 % prevalence of loss protective sensation. The Ipswich touch test demonstrated a good diagnostic accuracy, with a sensitivity of 70.8 %, specificity of 98.6 %, and an area under the curve of 0.85 when compared to 10-g monofilament. Positive and negative predictive values were 94.4 % and 90.8 % respectively. The positive likelihood ratio was 49.82, and the negative likelihood ratio was 0.30. Interrater reliability, assessed with two raters in a subset of 93 participants, yielded a kappa of 0.88, indicating almost perfect agreement.

CONCLUSIONS

The Ipswich Touch Test demonstrated good accuracy and interrater reliability compared to the standard 10-g monofilament, thus establishing its effectiveness as a valuable diagnostic tool for identifying loss of protective sensation among diabetic patients. However, its relatively low sensitivity suggests it should be used with caution as a screening tool.

摘要

目的

评估伊普斯威奇触觉测试与10克单丝测试相比,在识别泰国糖尿病患者保护性感觉丧失方面的准确性。

方法

对在门诊糖尿病诊所进行常规年度足部检查的泰国糖尿病患者进行了一项横断面观察性研究。通过伊普斯威奇触觉测试评估保护性感觉丧失情况,并与Semmes-Weinstein 10克单丝测试进行比较。计算敏感性、特异性、预测值和似然比,以衡量伊普斯威奇触觉测试相对于10克单丝作为参考标准的准确性。由两名评估者评估伊普斯威奇触觉测试的评估者间可靠性。

结果

在一项对283名糖尿病患者的研究中,10克单丝检测出保护性感觉丧失的患病率为25%。与10克单丝相比,伊普斯威奇触觉测试显示出良好的诊断准确性,敏感性为70.8%,特异性为98.6%,曲线下面积为0.85。阳性和阴性预测值分别为94.4%和90.8%。阳性似然比为49.82,阴性似然比为0.30。在93名参与者的子集中由两名评估者评估的评估者间可靠性,kappa值为0.88,表明几乎完全一致。

结论

与标准的10克单丝相比,伊普斯威奇触觉测试显示出良好的准确性和评估者间可靠性,从而确立了其作为识别糖尿病患者保护性感觉丧失的有价值诊断工具的有效性。然而,其相对较低的敏感性表明,作为筛查工具应谨慎使用。