Suppr超能文献

[可吸收缝线(PDS)用于肌腱缝合的经验]

[Experiences with a resorbable suture (PDS) in tendon sutures].

作者信息

Bruck J C, Schlögel R

出版信息

Handchir Mikrochir Plast Chir. 1985 Jul;17(4):238-40.

PMID:3928460
Abstract

67 tendon sutures were performed on 29 patients using polydioxanon (PDS), a synthetic absorbable suture material. The results after a mean survey period of twelve months are documented; there were no ruptures and fistula, only two infections and in four cases the need for tenolysis. In the reconstruction of isolated flexor tendon injuries 89% excellent results were found. The satisfactory and bad results in reconstructing flexor and extensor tendon injuries accompanied by complex hand injuries are analyzed and discussed.

摘要

使用聚二氧六环酮(PDS,一种合成可吸收缝合材料)对29例患者进行了67次肌腱缝合。记录了平均12个月的随访期后的结果;没有出现破裂和瘘管,仅发生两例感染,4例需要进行肌腱松解术。在孤立性屈肌腱损伤的重建中,89%的结果为优。对伴有复杂手部损伤的屈肌腱和伸肌腱损伤重建中的满意结果和不良结果进行了分析和讨论。