Suppr超能文献

在尼日利亚,实验室工作人员对Truenat作为结核病新诊断工具易用性的认知:试点推广结果

Perceived ease of use of Truenat among laboratory staff as a new diagnostic tool for TB in Nigeria: Result of a pilot roll-out.

作者信息

Ihesie Austin, Nwokoye Nkiru, Olabamiji Jamiu, Ochei Kingsley, Eneogu Rupert, Nongo Debby, Babayi Aminu, Olugbemiga Rayi, Odume Bethrand, Agbaje Aderonke, Oyelaran Omosalewa, van Germert Wayne, Mupfumi Lucy, Amos Omoniyi, Emeka Elom, Anyaike Chukwuma, Ossai Edmund Ndudi

机构信息

HIV AIDS & TB Office, USAID Nigeria, Abuja, Nigeria.

KNCV Nigeria, Abuja, Nigeria.

出版信息

PLOS Glob Public Health. 2024 Sep 20;4(9):e0003652. doi: 10.1371/journal.pgph.0003652. eCollection 2024.

Abstract

In January 2020, WHO released a rapid communication on use of molecular assays as initial tests for diagnosis of tuberculosis, recommending Truenat as a replacement for smear microscopy in TB diagnosis. This study was designed to assess perceived ease of use of Truenat among Laboratory staff as a new diagnostic tool for TB in Nigeria. This study used a cross-sectional design. All trained Laboratory personnel operating the Truenat Duo equipment in 38 Truenat sites in the country were included. Information was obtained using a pre-tested self-administered questionnaire. Ease of use of Truenat was assessed using twenty-three variables on a five-point Likert scale of 1-5. The variables were analyzed quantitatively and qualitatively. Good Ease of use of Truenat was determined by proportion of respondents who answered ≥70% of the variables in the positive. All 50 Truenat Laboratory staff participated in the study. (Response rate 100%). Majority, (58%) were male. The median estimated number of tests before Laboratory staff became proficient with Truenat machine was 9 (IQR, 4-20), median number of tests to be analyzed within eight working hours was 10, (IQR = 8-15) and median time to conduct a Truelab MTBPlus test from start to finish was 60 minutes (IQR = 60-80). The commonest operational challenge that required Molbio service support was Trueprep errors/blockage, 47.4%. Overall, mean ease of use score was 4.0±0.4. Majority, (76%) had Good Ease of use of Truenat. No factor significantly influenced Ease of use of Truenat. Truenat machine is easy to use for a trained laboratory staff with minimal technical support and hence could be rolled out easily and successfully by various National TB Programs. Considering the high Trueprep challenges reported, there is need for further studies into the common errors/challenges, the contexts surrounding them and the programmatic intervention to address the high rate of Trueprep equipment faults.

摘要

2020年1月,世界卫生组织发布了一份关于使用分子检测作为结核病诊断初始检测方法的快速通报,推荐将TrueNat作为结核病诊断中涂片显微镜检查的替代方法。本研究旨在评估尼日利亚实验室工作人员对TrueNat作为结核病新诊断工具的易用性感知。本研究采用横断面设计。纳入了该国38个TrueNat检测点所有操作TrueNat Duo设备的经过培训的实验室人员。通过一份预先测试的自填式问卷获取信息。使用23个变量在1 - 5的五点李克特量表上评估TrueNat的易用性。对这些变量进行了定量和定性分析。TrueNat良好的易用性由回答≥70%变量为肯定的受访者比例确定。所有50名TrueNat实验室工作人员参与了研究(回复率100%)。大多数(58%)为男性。实验室工作人员熟练使用TrueNat机器之前的估计测试次数中位数为9次(四分位间距,4 - 20),八个工作小时内要分析的测试次数中位数为10次(四分位间距 = 8 - 15),完成一次TrueLab MTBPlus检测从开始到结束的时间中位数为60分钟(四分位间距 = 60 - 80)。需要Molbio服务支持的最常见操作挑战是Trueprep错误/堵塞,占47.4%。总体而言,易用性平均得分是4.0±0.4。大多数(76%)对TrueNat的易用性评价良好。没有因素对TrueNat的易用性有显著影响。对于经过培训且技术支持需求 minimal 的实验室工作人员来说,TrueNat机器易于使用,因此各个国家结核病规划可以轻松且成功地推广。考虑到报告的Trueprep挑战较高,有必要进一步研究常见错误/挑战、其周围环境以及解决Trueprep设备高故障率的规划干预措施。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2303/11414918/8c4c124e2b37/pgph.0003652.g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验