Department of Orthopedics and Traumatology, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Praxis für Gelenkchirurgie Bad Kreuznach, 55543, Bad Kreuznach, Germany.
Int Orthop. 2024 Dec;48(12):3101-3108. doi: 10.1007/s00264-024-06325-y. Epub 2024 Sep 25.
Despite numerous studies demonstrating promising short-term outcomes of Total Knee Arthroplasty (TKA) with Customized Individually Made (CIM) implants, there is a significant lack of data on their mid-term effectiveness. Given the increasing number of TKAs performed annually, the rising demand for CIM implants, and the associated burden of revision surgeries, understanding the mid-term performance of CIM implants is crucial. Therefore, this study aims to report on the mid-term (minimum 5 years) outcomes of TKA using a CIM implant.
This retrospective cohort study included a consecutive series of 116 patients who received the ConforMIS iTotal CR implant between 2015 and 2018. Inclusion criteria were end-stage knee osteoarthritis with coronal deformities below 10° and absence of ligamentous instability. Exclusion criteria included simultaneous bilateral TKA. Patients were followed up at a minimum of five years post-surgery. They completed a questionnaire reporting on satisfaction, pain levels using the Visual Analogue Scale (VAS), current weight, the Oxford Knee Score (OKS), and the Forgotten Joint Score for the knee (FJS-knee). Statistical analysis included descriptive statistics for demographic and clinical variables, and outcomes were reported as means with ranges.
The mean follow-up duration was 5.9 ± 0.8 years (range 5-7.4 years). 90% of patients stated they would undergo the same operation again, and 93% were either satisfied or very satisfied. The mean VAS for pain at rest was 2 ± 1.5 (range 0-6) and during exercise was 3 ± 2 (range 0-8). 58 patients (53%) managed to lose weight. The mean OKS was 41 ± 9 points (range 15-48), and the mean FJS-knee was 67 ± 23 points (range 4-100). No severe complications occurred.
CIM TKA using the ConforMIS iTotal CR implant can achieve excellent results with 93% of patients being satisfied or very satisfied at mid-term follow-up of five years. Prospective, randomized, and patient-blinded trials comparing off-the-shelf (OTS) TKAs with CIM implants are necessary to evaluate whether these implants are superior or not.
尽管有大量研究表明定制个体化假体全膝关节置换术(TKA)具有良好的短期疗效,但关于其中期疗效的数据仍严重缺乏。鉴于每年 TKA 手术数量的增加、对定制个体化假体的需求增加以及翻修手术相关的负担,了解定制个体化假体的中期表现至关重要。因此,本研究旨在报告使用定制个体化假体的 TKA 的中期(至少 5 年)结果。
这是一项回顾性队列研究,纳入了 2015 年至 2018 年间接受 ConforMIS iTotal CR 假体的 116 例连续患者。纳入标准为伴有冠状面畸形且<10°的终末期膝骨关节炎,且无韧带不稳定。排除标准为同期行双侧 TKA。患者术后至少随访 5 年。他们完成了一份问卷,报告满意度、视觉模拟量表(VAS)疼痛评分、当前体重、牛津膝关节评分(OKS)和膝关节遗忘关节评分(FJS-knee)。统计分析包括人口统计学和临床变量的描述性统计,结果以平均值及范围表示。
平均随访时间为 5.9±0.8 年(5-7.4 年)。90%的患者表示愿意再次接受相同的手术,93%的患者表示满意或非常满意。静息时 VAS 疼痛平均为 2±1.5(0-6),运动时为 3±2(0-8)。58 例(53%)患者成功减重。平均 OKS 为 41±9 分(15-48),平均 FJS-knee 为 67±23 分(4-100)。无严重并发症发生。
使用 ConforMIS iTotal CR 假体的定制个体化 TKA 可获得优异的结果,93%的患者在 5 年的中期随访时表示满意或非常满意。需要前瞻性、随机、患者盲法的临床试验来比较即市假体(OTS)TKA 与定制个体化假体,以评估这些假体是否更具优势。