Suppr超能文献

使用新型一次性软性输尿管镜并进行实时肾内压监测评估肾内压——猪模型实验研究

The Evaluation of Intrarenal Pressure Using a Novel Single-Use Flexible Ureteroscope with Live Intrarenal Pressure Monitoring-An Experimental Study in Porcine Models.

作者信息

Samaras Angelos, Tatanis Vasileios, Peteinaris Angelis, Obaidat Mohammed, Faitatziadis Solon, Vagionis Athanasios, Spinos Theodoros, Mylonopoulou Marina, Kallidonis Panagiotis, Liatsikos Evangelos

机构信息

Department of Urology, University Hospital of Patras, 26504 Rio, Greece.

Department of Urology, Medical University of Vienna, 1090 Vienna, Austria.

出版信息

Life (Basel). 2024 Aug 24;14(9):1060. doi: 10.3390/life14091060.

Abstract

(1) Background: This study aims to evaluate how different irrigation settings and the use of ureteral access sheaths (UASs) of varying sizes impact intrarenal pressure (IRP) during flexible ureteroscopy (fURS) procedures in pigs. (2) Methods: This study utilized three anesthetized female pigs. A novel flexible ureteroscope with the ability to continuously record live intrarenal pressure was used to perform ureteroscopy in different settings. Ureteroscopy was performed without UAS and with the use of 11/13 and 12/14 UAS at the ureteropelvic junction. Two different irrigation methods were employed for each parameter: one using gravity flow and the other using manual pumping with a commercial pump. IRP was also recorded with the presence of a laser fiber or lithotripsy basket. (3) Results: The recorded mean IRP during flexible URS without UAS was 28.25 (±11.2) under gravity irrigation; 35.46 (±10.08) under manual pumping; 22.5 (±3.05) and 30.75 (±5.79) with a laser fiber under gravity irrigation and manual pumping, respectively; and 16.45 (±1.27) and 17.27 (±3.69) with a lithotripsy basket under gravity irrigation and manual pumping, respectively. With an 11/13 UAS, the mean IRP was 15.41 (±8.57) and 19.33 (±4.26) under gravity and manual pumping irrigation, respectively; 14.56 (±2.50) and 18.64 (±5.13) with a laser in each irrigation setting, respectively; and 13.10 (±3.39) and 13.86 (±4.63) with a lithotripsy basket, respectively. With a 12/14 UAS, the mean IRP was 7.64 (±3.08) and 9.25 (±1.42) under gravity and manual pumping irrigation, respectively; 9.50 (±6.04) and 10.28 (3.46), respectively, in each setting when the laser fiber was used; and 5.32 (±1.57) and 6.26 (±1.79), respectively, when the lithotripsy basket was inserted. (4) Conclusion: Novel flexible ureteroscopes with integrated pressure sensors are both a feasible and reliable tool during fURS, giving the surgeon the ability to live-track the IRP. The results of the IRP measurements with and without UAS are in accordance with the current literature and exhibit a consistent pattern with previous studies.

摘要

(1) 背景:本研究旨在评估在猪的软性输尿管镜检查(fURS)过程中,不同的冲洗设置以及使用不同尺寸的输尿管通路鞘(UAS)如何影响肾内压(IRP)。(2) 方法:本研究使用了三只麻醉的雌性猪。采用一种新型的能够连续记录实时肾内压的软性输尿管镜,在不同的设置下进行输尿管镜检查。在输尿管肾盂连接处不使用UAS以及使用11/13和12/14的UAS进行输尿管镜检查。每个参数采用两种不同的冲洗方法:一种使用重力流,另一种使用商用泵进行手动泵注。在有激光光纤或碎石篮的情况下也记录IRP。(3) 结果:在不使用UAS的软性输尿管镜检查期间,重力冲洗下记录的平均IRP为28.25(±11.2);手动泵注下为35.46(±10.08);在重力冲洗和手动泵注下,有激光光纤时分别为22.5(±3.05)和30.75(±5.79);在重力冲洗和手动泵注下,有碎石篮时分别为16.45(±1.27)和17.27(±3.69)。使用11/13的UAS时,重力冲洗和手动泵注冲洗下的平均IRP分别为15.41(±8.57)和19.33(±4.26);在每种冲洗设置下,有激光时分别为14.56(±2.50)和18.64(±5.13);有碎石篮时分别为13.10(±3.39)和13.86(±4.63)。使用12/14的UAS时,重力冲洗和手动泵注冲洗下的平均IRP分别为7.64(±3.08)和9.25(±1.42);使用激光光纤时,每种设置下分别为9.50(±6.04)和10.28(3.46);插入碎石篮时分别为5.32(±1.57)和6.26(±1.79)。(4) 结论:带有集成压力传感器的新型软性输尿管镜在fURS期间是一种可行且可靠的工具,使外科医生能够实时跟踪IRP。使用和不使用UAS时的IRP测量结果与当前文献一致,并且与先前的研究呈现出一致的模式。