Suppr超能文献

建立健康绝经后女性阴道前庭弹性成像的参考值。

Establishing Reference Values for Vaginal Vestibule Elastography in Healthy Postmenopausal Women.

作者信息

Okui Nobuo

机构信息

Dentistry, Kanagawa Dental University, Kanagawa, JPN.

Urogynecology, Yokosuka Urogynecology and Urology Clinic, Kanagawa, JPN.

出版信息

Cureus. 2024 Aug 31;16(8):e68294. doi: 10.7759/cureus.68294. eCollection 2024 Aug.

Abstract

Objective This study aims to establish normative elastography values for the vaginal vestibule in healthy postmenopausal women and assess the variability of these values with age and measurement time during the day. Methods The study included 111 women aged 40-90, excluding those with medical histories or treatments affecting vaginal health. Elastography measurements were taken twice daily, between 9-10 AM and 3-4 PM, using real-time tissue elastography technology. Statistical analysis evaluated the effects of age, body mass index (BMI), and diurnal variation on vaginal vestibule elasticity. Results A significant positive correlation between age and elastography values was found (p=8.36×10⁻⁷), with elastography values increasing by approximately 0.0040 units per year. The mean elastography value was 28.32% (SD=5.87%) in the morning and 28.10% (SD=5.90%) in the afternoon, with a statistically significant difference (p=0.016). BMI showed a weak negative correlation with elastography values (r=-0.2021, p=0.0334). Conclusion Establishing reference values for vaginal vestibule elastography provides a foundation for improved diagnostic accuracy and early detection of gynecological conditions. The findings support the use of elastography as a non-invasive, reliable diagnostic tool in clinical practice. Future research should validate these results across different age groups and in women with specific gynecological conditions to further solidify the clinical applicability of vaginal vestibule elastography.

摘要

目的 本研究旨在建立健康绝经后女性阴道前庭弹性成像的正常参考值,并评估这些值随年龄和一天中测量时间的变化情况。方法 该研究纳入了111名年龄在40 - 90岁之间的女性,排除有影响阴道健康病史或治疗史的女性。使用实时组织弹性成像技术,每天上午9 - 10点和下午3 - 4点各进行一次弹性成像测量。统计分析评估年龄、体重指数(BMI)和昼夜变化对阴道前庭弹性的影响。结果 发现年龄与弹性成像值之间存在显著正相关(p = 8.36×10⁻⁷),弹性成像值每年增加约0.0040单位。上午的平均弹性成像值为28.32%(标准差 = 5.87%),下午为28.10%(标准差 = 5.90%),差异具有统计学意义(p = 0.016)。BMI与弹性成像值呈弱负相关(r = -0.2021,p = 0.0334)。结论 建立阴道前庭弹性成像的参考值为提高妇科疾病的诊断准确性和早期检测提供了基础。这些发现支持将弹性成像作为临床实践中一种非侵入性、可靠的诊断工具。未来的研究应在不同年龄组以及患有特定妇科疾病的女性中验证这些结果,以进一步巩固阴道前庭弹性成像的临床适用性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/958e/11441113/93105e8e8bc3/cureus-0016-00000068294-i01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验