The purpose of this study was to develop a new instrument to measure the mechanical properties of rotary endodontic Ni-Ti files (ProTaper Gold F2, ProTaper Ultimate F2, and HyFlex EDM Onefile), and to evaluate the overall utility of the device. The instrument was capable of analyzing the 6-axis force/torque generated by the files during cyclic dynamic movement in a metal curved artificial root canal, and doing automatic cyclic dynamic filing in a resin root canal with a preset vertical force limit by adopting a negative feedback mechanism. By analyzing the 6-axis force/torque, we were able to estimate the position and contact points of the files in the curved root canal. ProTaper Gold showed the highest force/torque in all directions. HyFlex EDM had the highest hysteresis ratio, centering ratio value and NCF (number of cycles to fatigue fracture), while the lowest vertical force.
本研究的目的是开发一种新仪器,用于测量旋转式镍钛根管锉(ProTaper Gold F2、ProTaper Ultimate F2和HyFlex EDM Onefile)的机械性能,并评估该装置的整体实用性。该仪器能够分析锉在金属弯曲人工根管内循环动态运动过程中产生的六轴力/扭矩,并通过采用负反馈机制在树脂根管内以预设垂直力极限进行自动循环动态锉削。通过分析六轴力/扭矩,我们能够估计锉在弯曲根管中的位置和接触点。ProTaper Gold在所有方向上显示出最高的力/扭矩。HyFlex EDM具有最高的滞后率、定心率值和NCF(疲劳断裂循环次数),而垂直力最低。