The quantitation of glycated hemoglobin (Hb A1c) represents an average blood glucose level for a period of 2 to 3 months for diagnosing, monitoring, and managing diabetes mellitus. Unreliable results are reported when hemoglobin (Hb) variants are present in the sample. Patients are advised to use an alternate method due to the presence of the variant Hb and a reflex test to Hb electrophoresis to obtain precise information about the Hb variant. The present study utilizes x axis values from Hb A1c capillary electrophoresis (CE) to identify clinically significant Hb variants Hb E, S, and D.
Patient samples (n = 60) that showed a variant peak in the Hb A1c test with an x axis value of 190 to 240 were selected for the study. The migration position of the Hb variant (x axis value) and variant percent of the Hb A1c test were compared with the x axis value and variant percent in the Hb electrophoresis test to presumptively identify the variants. The identity of the variants was confirmed using mass spectrometry (MS).
Out of 60 samples, 20 samples were identified as Hb E (x axis 225-227), 20 samples were identified as Hb S (x axis 210-214), and 18 samples were identified as Hb D-Punjab (x axis 200-201). Two variants with an x axis value of 194 were identified as an α variant Hb Q India using MS. There is an overall negative shift of the x axis (-1 to -13 units) and a lower variant percent (-0.2% to -8.7%) in Hb A1c CE when compared with Hb electrophoresis.
The present study highlights the significance of the x axis value and variant percent to identify clinically significant Hb variants in the Hb A1c CE test.
糖化血红蛋白(Hb A1c)的定量检测代表了2至3个月期间的平均血糖水平,用于糖尿病的诊断、监测和管理。当样本中存在血红蛋白(Hb)变异体时,会报告不可靠的结果。由于存在变异Hb,建议患者使用替代方法,并进行Hb电泳的反射试验,以获取有关Hb变异体的精确信息。本研究利用Hb A1c毛细管电泳(CE)的x轴值来识别具有临床意义的Hb变异体Hb E、S和D。
选择在Hb A1c检测中显示变异峰且x轴值为190至240的患者样本(n = 60)进行研究。将Hb变异体的迁移位置(x轴值)和Hb A1c检测的变异百分比与Hb电泳检测中的x轴值和变异百分比进行比较,以推测性地识别变异体。使用质谱(MS)确认变异体的身份。
在60个样本中,20个样本被鉴定为Hb E(x轴225 - 227),20个样本被鉴定为Hb S(x轴210 - 214),18个样本被鉴定为Hb D - 旁遮普(x轴200 - 201)。使用MS将两个x轴值为194的变异体鉴定为α变异体Hb Q印度型。与Hb电泳相比,Hb A1c CE中x轴总体负移(-1至-13单位)且变异百分比更低(-0.2%至-8.7%)。
本研究强调了在Hb A1c CE检测中x轴值和变异百分比对于识别具有临床意义的Hb变异体的重要性。