Dogandzhiyska Violeta, Tsenova-Ilieva Irina, Raykovska Miriana, Karova Emilia
Department of Conservative Dentistry, Faculty of Dental Medicine, Medical University, Sofia, Bulgaria.
IICT-BAS, Bulgaria.
J Int Soc Prev Community Dent. 2024 Aug 27;14(4):325-331. doi: 10.4103/jispcd.jispcd_198_23. eCollection 2024 Jul-Aug.
To compare the efficiency of root canal filling removal from oval-shaped root canals with high-energy Er:YAG laser and additional instrumentation with a rotary Ni-Ti XP-Endo Finisher R system.
The study was accomplished on 12 freshly extracted single-rooted mandibular incisors with one straight oval-shaped root canal, shaped with XP-Endo Shaper 30/.04 and obturated by using the warm vertical condensation technique subjected to further endodontic orthograde retreatment. Group 1: the first retreatment was carried out using a high-energy Er:YAG laser ( = 12). Group 2: the additional retreatment of the same specimens was performed with the XP-Endo Finisher-R system ( = 12). The effectiveness of the retreatment techniques was evaluated by a threefold micro-CT examination. The amount of the remaining root canal filling material was analyzed by Mann-Whitney test and Friedman tests.
A significant decrease in the quantity of the root canal filling was found following the first and after the second retreatment, compared to the initial values in all examined sections ( < 0.001). Within groups, additional application of the Ni-Ti system resulted in no significant removal of the filling materials ( > 0.05).
None of the systems resulted in complete root canal filling removal. Despite the improved results after the application of the supplementary retreatment protocol, none of the root canal walls were completely clean in the apical area. The high-energy Er:YAG laser and XP-Endo Finisher R rotary system can be successfully used in endodontic orthograde retreatment under relevant operating parameters.
比较高能Er:YAG激光与使用旋转镍钛XP-Endo Finisher R系统进行额外器械操作从椭圆形根管中去除根管充填物的效率。
对12颗新鲜拔除的单根下颌切牙进行研究,这些牙齿均有一条直的椭圆形根管,先用XP-Endo Shaper 30/.04进行根管预备,然后采用热垂直加压技术进行充填,之后进行进一步的牙髓病正行再治疗。第1组:使用高能Er:YAG激光进行首次再治疗(n = 12)。第2组:对相同标本使用XP-Endo Finisher-R系统进行额外的再治疗(n = 12)。通过三次显微CT检查评估再治疗技术的有效性。采用Mann-Whitney检验和Friedman检验分析剩余根管充填材料的量。
与所有检查部位的初始值相比,首次和第二次再治疗后根管充填物的量均显著减少(P < 0.001)。在组内,额外应用镍钛系统并未导致充填材料的显著去除(P > 0.05)。
两种系统均未完全去除根管充填物。尽管应用补充再治疗方案后结果有所改善,但根尖区的根管壁均未完全清洁。在相关操作参数下,高能Er:YAG激光和XP-Endo Finisher R旋转系统可成功用于牙髓病正行再治疗。