XP-endo Finisher R 器械优化了在椭圆形根管中去除根充残余物的效果。

XP-endo Finisher R instrument optimizes the removal of root filling remnants in oval-shaped canals.

机构信息

Department of Endodontics, Fluminense Federal University, Niterói, Rio de Janeiro, Brazil.

Department of Dentistry II, Federal University of Maranhão, São Luís, Maranhão, Brazil.

出版信息

Int Endod J. 2019 Jun;52(6):899-907. doi: 10.1111/iej.13077. Epub 2019 Feb 15.

Abstract

AIM

To evaluate the performance of XP-endo Finisher R instruments when removing root filling remnants from oval-shaped canals using microcomputed tomographic (micro-CT) imaging as the analytical tool. Passive ultrasonic irrigation (PUI) was used as a reference technique for comparison.

METHODOLOGY

Twenty mandibular incisors with oval-shaped canals were matched based on similar anatomic features of the canal (volume, aspect ratio and 3D configuration) after scanning procedures. The canals were prepared with Reciproc R25 instruments, filled with gutta-percha and AH Plus sealer using the single-cone technique and retreated up to a Reciproc R40 instrument. After retreatment procedures, the specimens were rescanned, and the homogeneity between the specimens, the oval-shaped anatomy and the remaining filling material were confirmed. The pair-matched samples were assigned to two experimental groups (n = 10), according to the supplementary approach used: XP-endo Finisher R or PUI. Each sample was scanned after each endodontic procedure. The volume of remaining root filling material was quantified before and after the use of each supplementary approach. This analysis was performed considering the total canal (Student t-test) and also by thirds (anova procedure followed by a Bonferroni correction). Data were analysed statistically with a significance level of 5%.

RESULTS

The volume of root filling material at baseline was similar between the groups (t-test, P = 0.787). XP-endo Finisher R removed significantly more root filling material compared to PUI (t-test, P = 0.015), as it removed a mean of ≅32% material compared to 12% for the PUI. There was no difference in the amount of root filling material removed in the root canal thirds after using both supplementary approaches (one-way anova, P = 0.07 for XP-endo Finisher R and P = 0.886 for PUI).

CONCLUSIONS

Both supplementary approaches significantly reduced the volume of remaining root filling material from oval-shaped canals. The XP-endo Finisher R instrument removed significantly more root filling material than PUI. None of the supplementary approaches was able to render oval-shaped canals completely free from remaining root filling material.

摘要

目的

使用微计算机断层扫描(micro-CT)成像作为分析工具,评估 XP-endo Finisher R 器械从椭圆形根管中去除根管充填残留物的性能。使用被动超声冲洗(PUI)作为比较的参考技术。

方法

在扫描程序后,根据根管(体积、纵横比和 3D 形态)的相似解剖特征,将 20 颗下颌切牙匹配为椭圆形根管。使用 Reciproc R25 器械预备根管,采用单尖技术用牙胶和 AH Plus 密封剂充填,并使用 Reciproc R40 器械进行再处理。再处理程序后,对标本进行重新扫描,并确认标本之间、椭圆形解剖结构和剩余充填材料的均匀性。根据使用的补充方法,将配对样本分为两组实验(n=10):XP-endo Finisher R 或 PUI。在每个根管治疗程序后,每个样本都进行扫描。在使用每种补充方法前后,定量剩余根管充填材料的体积。考虑到整个根管(Student t 检验)和三分之一(anova 程序后进行 Bonferroni 校正)进行了这种分析。用 5%的显著水平进行统计数据分析。

结果

两组基线时根管充填材料的体积相似(t 检验,P=0.787)。与 PUI 相比,XP-endo Finisher R 去除的根管充填材料明显更多(t 检验,P=0.015),因为它去除的平均材料量约为 32%,而 PUI 为 12%。使用两种补充方法后,在根管的三分之一处,根管内充填材料的去除量没有差异(one-way anova,XP-endo Finisher R 为 P=0.07,PUI 为 P=0.886)。

结论

两种补充方法都显著减少了椭圆形根管中剩余根管充填材料的体积。XP-endo Finisher R 器械去除的根管内充填材料明显多于 PUI。两种补充方法均未能使椭圆形根管完全无剩余根管内充填材料。