Suppr超能文献

使用内镜固定器的单手与双手内镜耳手术对比:单中心研究

Conventional one-handed compared to two-handed endoscopic ear surgery using an endoscope holder: a single center study.

作者信息

Müller Christoph, Raczynski Anastasia, Lailach Susen, Zahnert Thomas

机构信息

TU Dresden, Faculty of Medicine and University Hospital Carl Gustav Carus, Department of Otorhinolaryngology Head and Neck Surgery, Ear Research Center Dresden, Fetscherstraße 74, Dresden, 01307, Germany.

出版信息

Eur Arch Otorhinolaryngol. 2025 Mar;282(3):1217-1230. doi: 10.1007/s00405-024-09018-9. Epub 2024 Oct 15.

Abstract

INTRODUCTION

One-handedness is a challenge in conventional endoscopic ear surgery (EES). We present results on the first-ever application of the passive endoscope holder 'Endofix exo' (Co. AKTORmed GmbH, Neutraubling, Germany) in EES, which enables two-handed surgery.

METHODS

This two-sided study compares cut-suture time, operating time, postoperative complications, graft take rates, hearing results and quality of life in patients who underwent first stage tympanoplasty due to tympanic membrane perforation with intact ossicular chain conditions. 25 patients received classic EES (EES-, mean age: 28 ± 21 years) and 15 received EES with the passive holder (EES+, mean age: 48 ± 21 years).

RESULTS

Mean operating times (EES-: 96 ± 38 (SD) min; EES+: 107 ± 33 min), cut-suture times (EES-: 68 ± 30 min; EES+: 73 ± 31 min), complications, graft take rates and hearing results (preoperative air bone gap (ABG) (PTA4): 15 dB ± SD 8 dB (EES-); 16 dB ± SD 8 dB (EES+); postoperative ABG (PTA4): 11.25dB ± SD 11.3dB (EES-); 14 dB ± SD 10 dB (EES+)) did not differ significantly (p > 0.05) between the two groups. Postoperative hearing results and quality of life tended to improve in both groups (p > 0.05).

DISCUSSION

The passive endoscope holder has been successfully applied during the course of the study. However, modifications of the endoscope holder and further studies are recommended focusing on positioning of grafts and prostheses to obtain conclusive results regarding the superiority of two-handed EES over one-handed conventional EES.

摘要

引言

在传统的耳内镜手术(EES)中,单手操作是一项挑战。我们展示了被动式内镜固定器“Endofix exo”(德国新特劳布林AKTORmed GmbH公司)在耳内镜手术中的首次应用结果,该固定器可实现双手操作。

方法

这项双侧研究比较了因鼓膜穿孔且听骨链完整而接受一期鼓室成形术患者的缝合时间、手术时间、术后并发症、移植物成活率、听力结果和生活质量。25例患者接受传统耳内镜手术(EES-,平均年龄:28±21岁),15例患者接受使用被动固定器的耳内镜手术(EES+,平均年龄:48±21岁)。

结果

两组之间的平均手术时间(EES-:96±38(标准差)分钟;EES+:107±33分钟)、缝合时间(EES-:68±30分钟;EES+:73±31分钟)、并发症、移植物成活率和听力结果(术前气骨导差(ABG)(PTA4):15分贝±标准差8分贝(EES-);16分贝±标准差8分贝(EES+);术后ABG(PTA4):11.25分贝±标准差11.3分贝(EES-);14分贝±标准差10分贝(EES+))差异均无统计学意义(p>0.05)。两组患者术后听力结果和生活质量均有改善趋势(p>0.05)。

讨论

在研究过程中,被动式内镜固定器已成功应用。然而,建议对内窥镜固定器进行改进并开展进一步研究,重点关注移植物和假体的定位,以得出双手操作的耳内镜手术优于单手传统耳内镜手术的确切结果。