Schwartz C, Nicolosi R, Lapinsky R, Grodman R
Am J Med. 1986 Jan;80(1):133-8. doi: 10.1016/0002-9343(86)90064-1.
The clinical usefulness and general ease of insertion of transvenous pacing catheters have made this procedure popular. It is sometimes difficult, yet important, to precisely locate the electrode tip. This report describes a patient in whom two-dimensional echocardiography was used to locate an aberrantly placed pacing catheter, whose position could not be established by conventional studies. Echocardiographic confirmation of the course taken by this pacing catheter has not been previously reported. The catheter was seen to pass from the aorta, through the aortic valve, into the body of the left ventricle.
经静脉起搏导管的临床实用性以及插入操作的总体简便性使得该操作很受欢迎。精确确定电极尖端的位置有时很困难,但却很重要。本报告描述了一名患者,在该患者中使用二维超声心动图来定位一根放置异常的起搏导管,而通过传统检查无法确定其位置。此前尚未有关于通过超声心动图确认该起搏导管走行的报道。可见该导管从主动脉穿过主动脉瓣进入左心室。