Novice nurses often find endotracheal suctioning signs unfamiliar. The Endotracheal Suction Assessment Tool© (ESAT©) aids pediatric nurses in suctioning but lacks an adult equivalent. A valid and reliable ESAT© for assessing intensive care unit patients' suction needs across different populations is necessary.
To test the validity and reliability of the ESAT© in adult ICU patients.
This methodological study assessed suction needs in patients at a tertiary adult ICU of a university hospital. Two independent observers used the ESAT© to determine suction needs. Data from 106 suction procedures were collected using a patient characteristics form, the ESAT©, and a suction monitoring form. The ESAT© includes eight respiratory and ventilation parameters and seven clinical consideration parameters. Hemodynamic and respiratory parameters were measured before, and one and five minutes after suction. Linguistic validity, content validity, and pilot testing were conducted. Interobserver agreement was evaluated, and psychometric evaluation was done using content validity index (CVI) and intraclass correlation coefficient (ICC). Data were analyzed with paired samples t-test and ANOVA.
Item CVI ranged from 0.80 to 1.00, and scale CVI was 0.96. Inter-item correlation and ICC for inter-rater reliability were both 0.933 (95 % CI = 0.903-0.954, p < 0.001 for ICC). Cohen's Kappa coefficients ranged from 0.690 to 1.000 (p < 0.001), indicating high consistency between raters for all tool items. All scale items showed near-perfect agreement except SpO2, which showed substantial agreement.
The S-CVI was good, indicating near-perfect agreement among raters. ESAT© is highly reliable and valid for determining suction needs in adult intensive care patients.
The ESAT© aids autonomous decision-making for suctioning needs. Originally for novice pediatric nurses, the ESAT© was adapted for adult intensive care nurses. The ESAT© is valid and reliable for adult intensive care patients.
新手护士常常觉得气管内吸痰的体征难以辨认。气管内吸痰评估工具(ESAT)有助于儿科护士进行吸痰操作,但缺乏适用于成人的同类工具。因此,需要一个有效且可靠的ESAT来评估不同人群中重症监护病房患者的吸痰需求。
检验ESAT在成人重症监护病房患者中的有效性和可靠性。
本方法学研究评估了一所大学医院三级成人重症监护病房患者的吸痰需求。两名独立观察者使用ESAT来确定吸痰需求。通过患者特征表、ESAT和吸痰监测表收集了106次吸痰操作的数据。ESAT包括八个呼吸和通气参数以及七个临床考量参数。在吸痰前、吸痰后1分钟和5分钟测量血流动力学和呼吸参数。进行了语言有效性、内容有效性和预试验。评估了观察者间的一致性,并使用内容效度指数(CVI)和组内相关系数(ICC)进行了心理测量学评估。数据采用配对样本t检验和方差分析进行分析。
项目CVI范围为0.80至1.00,量表CVI为0.96。评分者间信度的项目间相关性和ICC均为0.933(95%可信区间 = 0.903 - 0.954,ICC的p < 0.001)。Cohen's Kappa系数范围为0.690至1.000(p < 0.001),表明所有工具项目评分者之间具有高度一致性。除SpO2显示为实质性一致性外,所有量表项目均显示近乎完美的一致性。
S-CVI良好,表明评分者之间近乎完美的一致性。ESAT在确定成人重症监护患者的吸痰需求方面高度可靠且有效。
ESAT有助于自主决定吸痰需求。ESAT最初是为新手儿科护士设计的,现已适用于成人重症监护护士。ESAT对成人重症监护患者有效且可靠。