Suppr超能文献

70兆赫超高频率超声在外周神经损伤中的作用

The Role of 70-MHz Ultrahigh-Frequency Ultrasound in the Peripheral Nerve Injury.

作者信息

Marco Fogante, Nicola Carboni, Claudio Ventura, Corrado Tagliati, Giulio Argalia

机构信息

Maternal-Child, Senological, Cardiological Radiology and Outpatient Ultrasound, Department of Radiological Sciences, University Hospital of Marche, Ancona, Italy.

Radiology Department, AST Pesaro Urbino, Pesaro, Italy.

出版信息

J Clin Ultrasound. 2025 Mar-Apr;53(3):397-404. doi: 10.1002/jcu.23872. Epub 2024 Oct 21.

Abstract

AIM

High-frequency ultrasound with an 18-MHz probe (18 MHz-HFUS) plays a relevant role in the evaluation of peripheral nerve injury (PNI). Ultrahigh-frequency ultrasound with a 70-MHz probe (70 MHz-UHFUS) offers higher spatial resolution and could allow a better detection of PNI. This study aimed to compare the diagnostic performance of HFUS and UHFUS in PNI detection.

MATERIALS AND METHODS

In this retrospective study, were selected, between July 2022 and April 2024, 61 patients underwent HFUS, UHFUS, and nerve conduction study (NCS) for clinical suspicion of traumatic forearm PNI. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of HFUS and UHFUS in PNI detection were calculated and compared. NCS was used as the reference standard. Nonparametric statistical tests were used. A p value of < 0.05 was considered statistically significant.

RESULTS

Comparing the diagnostic performance in PNI detection, the 70 MHz-UHFUS showed a sensitivity and diagnostic accuracy significantly higher than 18 MHz-HFUS, respectively, 98.0% versus 82.4% (p = 0.0205) and 95.1% versus 82.0% (p = 0.0468). Otherwise, not significantly difference were in specificity, PPV, and NPV.

CONCLUSIONS

UHFUS compared to HFUS demonstrated a higher sensitivity and diagnostic accuracy in PNI detection.

摘要

目的

使用18兆赫探头的高频超声(18MHz - HFUS)在评估周围神经损伤(PNI)中发挥着重要作用。使用70兆赫探头的超高频率超声(70MHz - UHFUS)具有更高的空间分辨率,可能能更好地检测PNI。本研究旨在比较HFUS和UHFUS在PNI检测中的诊断性能。

材料与方法

在这项回顾性研究中,选取了2022年7月至2024年4月期间因临床怀疑创伤性前臂PNI而接受HFUS、UHFUS和神经传导研究(NCS)的61例患者。计算并比较了HFUS和UHFUS在PNI检测中的敏感性、特异性、阳性预测值(PPV)、阴性预测值(NPV)和诊断准确性。NCS被用作参考标准。使用非参数统计检验。p值<0.05被认为具有统计学意义。

结果

在比较PNI检测的诊断性能时,70MHz - UHFUS的敏感性和诊断准确性显著高于18MHz - HFUS,分别为98.0%对82.4%(p = 0.0205)和95.1%对82.0%(p = 0.0468)。否则,特异性、PPV和NPV无显著差异。

结论

与HFUS相比,UHFUS在PNI检测中表现出更高的敏感性和诊断准确性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验