Suppr超能文献

使用超高频率神经肌肉超声测定健康对照者近端神经束旋转程度:一项初步研究。

Determining the degree of proximal nerve fascicle rotation in healthy controls using ultrahigh-frequency neuromuscular ultrasound: A pilot study.

作者信息

Meiling James B, Penry Vanessa Baute, Miller Nicholas J, Cartwright Michael S, Sangio Christian A, Gandhi Mehta Rachana K

机构信息

Wake Forest University School of Medicine, Winston-Salem, North Carolina, USA.

出版信息

Muscle Nerve. 2025 Jan;71(1):108-112. doi: 10.1002/mus.28273. Epub 2024 Oct 31.

Abstract

INTRODUCTION/AIMS: Ultrahigh-frequency ultrasound (UHFUS) allows improved visualization and higher resolution images of nerve fascicles than standard high-frequency ultrasound. Dynamic UHFUS may detect the presence of fascicular entwinement, the recently described sonographic phenomenon of pathologic fascicular rotation seen in neuralgic amyotrophy. This pilot study aims to establish normative reference values and degrees of fascicular rotation for the proximal portions of commonly involved upper limb nerves in healthy controls using UHFUS.

METHODS

Twenty healthy participants underwent sonographic examination of the median, musculocutaneous, and radial nerves on both upper limbs using UHFUS with a 48 MHz linear transducer. A single rater assessed the degree of fascicular rotation in each peripheral nerve.

RESULTS

Fascicular rotation appears to occur in the proximal portion of each of these nerves. The mean degree of fascicular rotation for each of the measured nerves was median 94.5°, musculocutaneous 97.9°, and radial 50.9°. The maximum observed fascicular rotation in each nerve was 180°. Age, sex, height, weight, body mass index, and race did not predict degree of fascicular rotation (all p > .103). A single-factor ANOVA test showed the degree of fascicular rotation differed in median, musculocutaneous, and radial nerves (F = 4.748, p = .011).

DISCUSSION

UHFUS allows quantification of fascicular rotation in healthy controls in the median, musculocutaneous, and radial nerves, and provides normative data. The data from this pilot study may serve as control data for future comparative studies in conditions where fascicular rotation occurs, such as neuralgic amyotrophy.

摘要

引言/目的:与标准高频超声相比,超高频超声(UHFUS)能更好地显示神经束并提供更高分辨率的图像。动态UHFUS可能检测到束状缠绕的存在,这是一种最近在神经性肌萎缩中描述的病理性束状旋转的超声现象。本前瞻性研究旨在使用UHFUS为健康对照者上肢常见受累神经近端建立束状旋转的规范参考值和程度。

方法

20名健康参与者使用48MHz线性换能器的UHFUS对双侧上肢的正中神经、肌皮神经和桡神经进行超声检查。由一名评估者评估每条周围神经的束状旋转程度。

结果

这些神经的近端似乎都存在束状旋转。每条测量神经的平均束状旋转程度分别为:正中神经94.5°,肌皮神经97.9°,桡神经50.9°。每条神经观察到的最大束状旋转为180°。年龄、性别、身高、体重、体重指数和种族均不能预测束状旋转程度(所有p>0.103)。单因素方差分析显示正中神经、肌皮神经和桡神经的束状旋转程度存在差异(F=4.748,p=0.011)。

讨论

UHFUS能够对健康对照者正中神经、肌皮神经和桡神经的束状旋转进行量化,并提供规范数据。这项前瞻性研究的数据可作为未来在发生束状旋转的疾病(如神经性肌萎缩)中进行比较研究的对照数据。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验