Suppr超能文献

全内镜下经典 Bröstrom-Gould 技术:中期结果。

All-Inside Endoscopic Classic Bröstrom-Gould Technique: Medium-term Results.

机构信息

Department of Orthopaedic Surgery, National University Hospital, Singapore, Singapore.

Department of Orthopaedic Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore.

出版信息

Am J Sports Med. 2024 Nov;52(13):3330-3338. doi: 10.1177/03635465241285892. Epub 2024 Oct 23.

Abstract

BACKGROUND

Short-term results after arthroscopic/endoscopic lateral ligament repair for chronic lateral ankle instability have been satisfactory, although medium- to longer-term results are lacking.

PURPOSE/HYPOTHESIS: The purpose of this study was to report the medium-term results of an all-inside endoscopic classic Bröstrom-Gould procedure where both the both lateral ligaments and the inferior extensor retinaculum can be approached directly, interchanging between arthroscopy for intracapsular structures and endoscopy for extracapsular structures. It was hypothesized that the all-inside endoscopic classic Bröstrom-Gould procedure would produce sustainable good outcomes at a medium term of 5 years.

STUDY DESIGN

Case series; Level of evidence, 4.

METHODS

A prospective database for 43 patients who underwent an all-inside endoscopic classic Bröstrom-Gould repair of the anterior talofibular ligament and calcaneofibular ligament with inferior extensor retinaculum augmentation was reviewed. Patient details, American Orthopaedic Foot & Ankle Society score, Karlsson score, ankle activity score (AAS), and patient satisfaction were collected and analyzed.

RESULTS

The study cohort of 43 patients with a mean age of 29.4 years (SD, 11.9 years) were reviewed at a mean follow-up of 63.1 months (SD, 8.5 months). The American Orthopaedic Foot & Ankle Society scores showed significant improvement from a mean of 69.6 (SD, 13.9) to 93.7 (SD, 10.7), while the Karlsson score improved from 59.7 (SD, 14.5) to 91.5 (SD, 14.5) at the final follow-up. The AAS showed that 32 (74.4%) patients maintained or had improvement in the AAS, from a mean of 5.38 (SD, 2.8) to 5.41 (SD, 2.8), with a mean satisfaction rate of 9.1 (SD, 1.3). Although the remaining 11 patients had a reduced AAS, at a mean of 4.6 (SD, 2.6), they reported a mean satisfaction rate of 7.4 (SD, 2.9). There were no surgical complications or reoperations reported in this cohort, although there were 3 patients with recurrent instability at their last follow-up, resulting in a failure rate of 7%.

CONCLUSION

The current study is the first to report the medium-term outcomes of an all-inside endoscopic classic Bröstrom-Gould procedure. Overall, 93% of the patients had good functional outcomes, but approximately 25% of patients had decreased ankle activity levels at a mean of 5 years postoperatively, albeit with good satisfaction rates.

摘要

背景

关节镜/内镜下外侧副韧带修复慢性外侧踝关节不稳定的短期结果令人满意,尽管中至长期结果尚缺乏。

目的/假设:本研究的目的是报告一种全内视镜经典 Bröstrom-Gould 手术的中期结果,该手术可直接接近内外侧副韧带和下伸肌支持带,在关节镜下处理囊内结构,在内镜下处理囊外结构。假设全内视镜经典 Bröstrom-Gould 手术在 5 年的中期会产生可持续的良好结果。

研究设计

病例系列;证据水平,4 级。

方法

对 43 例接受全内视镜经典 Bröstrom-Gould 修复前距腓韧带和跟腓韧带并加强下伸肌支持带的患者进行前瞻性数据库回顾。收集并分析患者详细信息、美国矫形足踝协会评分、Karlsson 评分、踝关节活动评分(AAS)和患者满意度。

结果

43 例患者的研究队列平均年龄 29.4 岁(标准差,11.9 岁),平均随访 63.1 个月(标准差,8.5 个月)。美国矫形足踝协会评分从平均 69.6(标准差,13.9)显著改善至 93.7(标准差,10.7),而 Karlsson 评分从 59.7(标准差,14.5)改善至 91.5(标准差,14.5)。AAS 显示,32 例(74.4%)患者的 AAS 保持或改善,从平均 5.38(标准差,2.8)改善至 5.41(标准差,2.8),平均满意度为 9.1(标准差,1.3)。尽管其余 11 例患者的 AAS 降低,平均为 4.6(标准差,2.6),但他们的满意度平均为 7.4(标准差,2.9)。该队列中未报告手术并发症或再次手术,但在最后一次随访中有 3 例患者出现复发性不稳定,失败率为 7%。

结论

本研究首次报告了全内视镜经典 Bröstrom-Gould 手术的中期结果。总体而言,93%的患者功能结果良好,但约 25%的患者在术后平均 5 年时踝关节活动水平下降,但满意度较高。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验