使用声诺维的超声造影对肝脏局灶性病变进行诊断性检测的准确性:一项系统评价和荟萃分析。

Diagnostic Test Accuracy of Contrast-Enhanced Ultrasound With Sonazoid for Assessment of Focal Liver Lesions: A Systematic Review and Meta-Analysis.

作者信息

Tang Yongqing, Sasaki Shun-Ichi, Hawley Joshua, Peillon Aurélie, Sjöström Anders, Fuentes-Alburo Adolfo, Tranquart Francois

机构信息

GE Healthcare Ltd and its Afilliates, Shanghai, China.

GE Healthcare Ltd and its Afilliates, Tokyo, Japan.

出版信息

J Clin Ultrasound. 2025 Mar-Apr;53(3):510-524. doi: 10.1002/jcu.23879. Epub 2024 Oct 23.

Abstract

This meta-analysis examined the diagnostic accuracy of Sonazoid-enhanced ultrasonography (SZ-CEUS) in discriminating malignant from benign focal liver lesions (FLLs) and HCC from non-HCC FLLs. Finding relevant studies required a rigorous PubMed, EMBASE, and other database search. To distinguish malignant from benign FLLs, SZ-CEUS had a pooled sensitivity of 94% (95% CI: 0.91-0.95) and specificity of 84% (95%: 0.78-0.89). HCC distinction had 83% sensitivity and 96% specificity (95% CI: 0.80-0.85 and 0.95-0.97). SZ-CEUS accurately distinguishes malignant from benign FLLs and HCC from non-HCC lesions, especially smaller HCC lesions.

摘要

这项荟萃分析探讨了索纳造影剂增强超声(SZ-CEUS)在鉴别肝脏局灶性病变(FLL)的良恶性以及肝细胞癌(HCC)与非HCC的FLL方面的诊断准确性。查找相关研究需要对PubMed、EMBASE及其他数据库进行严格检索。为鉴别FLL的良恶性,SZ-CEUS的合并敏感度为94%(95%置信区间:0.91-0.95),特异度为84%(95%:0.78-0.89)。鉴别HCC的敏感度为83%,特异度为96%(95%置信区间:0.80-0.85和0.95-0.97)。SZ-CEUS能够准确鉴别FLL的良恶性以及HCC与非HCC病变,尤其是较小的HCC病变。