Młynarska Agnieszka, Młynarski Rafał
School of Health Sciences, Medical University of Silesia, Katowice, Poland.
Pol J Radiol. 2024 Sep 6;89:e428-e432. doi: 10.5114/pjr/191535. eCollection 2024.
Modern imaging techniques such as computed tomography (CT) can help in the assessment of coronary sinus volume in a vitro manner, but there is no comprehensive research on this topic so far. Hence, we decided to develop a methodology for measuring the volume of the coronary sinus in multi-detector CT and to try to apply it in practice.
Forty-nine patients (22 men) were included in this research, with a mean age of 70.08 ± 13.6 years. Scanning with retrospective ECG-gating was performed using a Toshiba Aquilion 64 (slice: 0.5 mm; helical pitch: 12.8; rotation time: 0.4 s). 80 ± 20 cm of non-ionic contrast was administered to each patient. The volume of coronary sinus and other data measurements were performed using Vitrea 2 workstations. The organ volume measurement function was used to measure volume objects in CT scans. To standardise the measurements, they were all performed to the place where the vein of Marshall reaches the coronary sinus. In cases of loss of vein of Marshall, the first lateral vein was used as the junction between the coronary sinus and the great cardiac vein.
The coronary sinus volume varied from 0.96 cm to 8.52 cm. The average volume was 3.71 ± 1.64 cm. There was a significant correlation between end diastolic volume and coronary sinus volume ( = 0.33, = 0.02). In most cases the quality of visualisation was good - the average was calculated as 4.16 ± 0.87. The Thebesian valve was present in 22 cases (44.9%); however, no statistical relationship between the presence of the Thebesian valve and coronary sinus was observed.
It is possible to visualise and calculate the volume of the coronary sinus in cardiac CT.
诸如计算机断层扫描(CT)等现代成像技术有助于以体外方式评估冠状窦容积,但目前尚无关于该主题的全面研究。因此,我们决定开发一种在多排CT中测量冠状窦容积的方法,并尝试将其应用于实践。
本研究纳入49例患者(22例男性),平均年龄70.08±13.6岁。使用东芝Aquilion 64进行回顾性心电图门控扫描(层厚:0.5mm;螺距:12.8;旋转时间:0.4s)。向每位患者注入80±20cm的非离子型对比剂。使用Vitrea 2工作站进行冠状窦容积及其他数据测量。利用器官容积测量功能测量CT扫描中的容积对象。为使测量标准化,所有测量均在马歇尔静脉汇入冠状窦处进行。若马歇尔静脉显示不清,则以第一侧静脉作为冠状窦与心大静脉的交界处。
冠状窦容积在0.96cm至8.52cm之间。平均容积为3.71±1.64cm。舒张末期容积与冠状窦容积之间存在显著相关性(=0.33,=0.02)。在大多数情况下,可视化质量良好——平均值计算为4.16±0.87。22例(44.9%)存在心最小静脉瓣;然而,未观察到心最小静脉瓣的存在与冠状窦之间的统计学关系。
在心脏CT中可视化并计算冠状窦容积是可行的。