Diffusion tensor imaging (DTI) provides insight into the skeletal muscle microstructure and can be acquired using a stimulated echo acquisition mode (STEAM)-based approach to quantify time-dependent tissue diffusion. This study examined diffusion metrics and signal-to-noise ratio (SNR) in the supraspinatus muscle obtained with a STEAM-DTI sequence with different diffusion encoding times (Δ) and compared them to measures from a spin echo (SE) sequence. Ten healthy subjects (mean age 31.5 ± 4.7 years; five females) underwent 3-Tesla STEAM and SE-DTI of the shoulder in three sessions. STEAM was acquired with Δ of 100/200/400/600 ms. The diffusion encoding time in SE scans was 19 ms (b = 500 s/mm). Region of interest-based measurement of fractional anisotropy (FA), mean diffusivity (MD), and SNR was performed. Intraclass correlation coefficients (ICCs) were computed to assess test-retest reliability. ANOVA with post-hoc pairwise tests was used to compare measures between different Δ of STEAM as well as STEAM and SE, respectively. FA was significantly higher (FA: 0.38-0.46 vs. FA: 0.26) and MD significantly lower (MD: 1.20-1.33 vs. MD: 1.62 × 10 mm/s) in STEAM compared to SE (p < 0.001, respectively). SNR was significantly higher for SE (72.3 ± 8.7) than for STEAM (p < 0.001). ICCs were excellent for FA in STEAM (≥0.911) and SE (0.960). For MD, ICCs were good for STEAM (≥0.759) and SE (0.752). STEAM and SE exhibited excellent reliability for FA and good reliability for MD in the supraspinatus muscle. SNR was significantly higher in SE compared to STEAM.
弥散张量成像(DTI)提供了对骨骼肌微观结构的深入了解,可以使用基于激发回波采集模式(STEAM)的方法来量化组织的时变扩散。本研究检查了不同扩散编码时间(Δ)的 STEAM-DTI 序列获得的冈上肌的扩散指标和信噪比(SNR),并将其与自旋回波(SE)序列的测量值进行了比较。10 名健康受试者(平均年龄 31.5±4.7 岁;女性 5 名)在三个阶段接受了肩部 3T STEAM 和 SE-DTI 检查。STEAM 的 Δ 分别为 100/200/400/600ms。SE 扫描的扩散编码时间为 19ms(b=500s/mm)。采用基于感兴趣区的分数各向异性(FA)、平均扩散系数(MD)和 SNR 测量。计算了组内相关系数(ICC)以评估测试-再测试的可靠性。分别采用方差分析和事后两两比较来比较不同 STEAM Δ之间以及 STEAM 和 SE 之间的测量值。与 SE 相比,STEAM 的 FA 显著更高(FA:0.38-0.46 vs. FA:0.26),MD 显著更低(MD:1.20-1.33 vs. MD:1.62×10mm/s)(p<0.001)。与 SE 相比,STEAM 的 SNR 显著更高(72.3±8.7)(p<0.001)。STEAM 的 ICC 对于 FA 为极好(≥0.911),对于 SE 为 0.960。对于 MD,STEAM 的 ICC 为极好(≥0.759),SE 的 ICC 为良好(≥0.752)。STEAM 和 SE 在冈上肌中均显示出 FA 极好的可靠性和 MD 良好的可靠性。与 STEAM 相比,SE 的 SNR 显著更高。