Suppr超能文献

游离腓骨瓣在下颌骨体部重建中羟基磷灰石/聚左旋乳酸固定的生物力学评估:结合材料特性和咀嚼功能评估的有限元分析

Biomechanical Evaluation of Hydroxyapatite/poly-l-lactide Fixation in Mandibular Body Reconstruction with Fibula Free Flap: A Finite Element Analysis Incorporating Material Properties and Masticatory Function Evaluation.

作者信息

Lee Sang-Min, Jung Tae-Gon, Kim Won-Hyeon, Kim Bongju, Lee Jee-Ho

机构信息

Department of Oral and Maxillofacial Surgery, Asan Medical Center, College of Medicine, University of Ulsan, 88 Olympic-ro, Songpa-gu, Seoul 05505, Republic of Korea.

Medical Device Development Center, Osong Medical Innovation Foundation, Chungju 28160, Republic of Korea.

出版信息

Bioengineering (Basel). 2024 Oct 11;11(10):1009. doi: 10.3390/bioengineering11101009.

Abstract

In reconstructive surgery following partial mandibulectomy, the biomechanical integrity of the fibula free flap applied to the remaining mandibular region directly influences the prognosis of the surgery. The purpose of this study is to evaluate the biomechanical integrity of two fixation materials [titanium (Ti) and hydroxyapatite/poly-L-lactide (HA-PLLA)]. In this study, we simulated the mechanical properties of miniplate and screw fixations in two different systems by finite element analysis. A three-dimensional mandibular model was constructed and a fibula free flap and reconstruction surface were designed. The anterior and posterior end of the free flap was positioned with two miniplates and two additional miniplates were applied to the angled area of the fibula. The masticatory loading was applied considering seven principal muscles. The peak von Mises stress (PVMS) distribution, size of fixation deformation, principal stresses on bones, and gap opening size were measured to evaluate the material properties of the fixation. In the evaluation of properties, superior results were observed with both fixation methods immediately after surgery. However, after the formation of callus between bone segments at 2 months, the performance of Ti fixation decreased over time and the differences between the two fixations became minimal by 6 months after surgery. The result of the study implies the positive clinical potential of the HA-PLLA fixation system applied in fibula free flap reconstruction.

摘要

在部分下颌骨切除术后的重建手术中,应用于剩余下颌骨区域的游离腓骨瓣的生物力学完整性直接影响手术预后。本研究的目的是评估两种固定材料[钛(Ti)和羟基磷灰石/聚-L-丙交酯(HA-PLLA)]的生物力学完整性。在本研究中,我们通过有限元分析模拟了两种不同系统中微型钢板和螺钉固定的力学性能。构建了一个三维下颌骨模型,并设计了一个游离腓骨瓣和重建表面。游离瓣的前端和后端用两块微型钢板定位,另外两块微型钢板应用于腓骨的成角区域。考虑七块主要肌肉施加咀嚼负荷。测量峰值冯·米塞斯应力(PVMS)分布、固定变形大小、骨上的主应力和间隙开口大小,以评估固定材料的性能。在性能评估中,术后立即观察到两种固定方法均有较好的结果。然而,在术后2个月骨段之间形成骨痂后,钛固定的性能随时间下降,术后6个月时两种固定之间的差异变得最小。该研究结果表明HA-PLLA固定系统在游离腓骨瓣重建中具有积极的临床应用潜力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/71ff/11505077/d76d0ec96c93/bioengineering-11-01009-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验