Firszt Oliver, Maślanka Magdalena, Grabowska Agata, Kluczewska Ewa
Doctoral Studies School, Medical University of Silesia, 40-055 Katowice, Poland.
Department of Radiology in Zabrze, Medical University of Silesia, 40-055 Katowice, Poland.
Children (Basel). 2024 Sep 30;11(10):1204. doi: 10.3390/children11101204.
Ultrasound (US) has been reported to be a reliable imaging modality for locating the tip of peripherally inserted central venous catheters (PICC) in neonates. However, its use requires a certain level of expertise, which may limit its application. Standardization of US examinations using designed protocols may improve their efficiency and ease of use. The objective of our study is to evaluate the effectiveness of introducing a standardized US protocol for PICC guidance. An expert panel was formed in order to develop a standardized US protocol for PICC assessment. Institutional review board agreement was obtained. This protocol was then used by participating clinicians to assess PICC position. Every assessment was followed by a radiographic control. The study group consisted of 262 US examinations of PICC lines in a level III neonatal intensive care unit (NICU) performed according to the designed protocol. Subsequent statistical analysis was made with the RStudio software, R version 4.3.1 (2023-06-16 ucrt). Compared to the X-ray control, standardized US examinations showed 100% sensitivity, 81% specificity, an accuracy of 98% and a 98% precision for assessing catheter placement. The Cohen's Kappa value for the comparison of X-ray and US studies was 0.88, indicating good agreement between the two methods. Standardized US examinations have shown similar potential for evaluating the location of PICC lines when compared with radiographic studies. Implementing a standardized protocol in the NICU may facilitate the ultrasound assessment of PICC lines and reduce exposure to ionizing radiation.
据报道,超声(US)是一种用于定位新生儿外周静脉中心导管(PICC)尖端的可靠成像方式。然而,其使用需要一定水平的专业知识,这可能会限制其应用。使用设计好的方案对超声检查进行标准化,可能会提高其效率和易用性。我们研究的目的是评估引入标准化超声方案用于PICC引导的有效性。成立了一个专家小组,以制定用于PICC评估的标准化超声方案。获得了机构审查委员会的同意。然后,参与的临床医生使用该方案来评估PICC的位置。每次评估后都进行X线对照检查。研究组包括在三级新生儿重症监护病房(NICU)按照设计方案进行的262次PICC导管超声检查。随后使用RStudio软件、R版本4.3.1(2023-06-16 ucrt)进行统计分析。与X线对照相比,标准化超声检查在评估导管位置时显示出100%的敏感性、81%的特异性、98%的准确性和98%的精确性。X线和超声研究比较的Cohen's Kappa值为0.88,表明两种方法之间具有良好的一致性。与X线研究相比,标准化超声检查在评估PICC导管位置方面显示出相似的潜力。在NICU实施标准化方案可能会促进对PICC导管的超声评估,并减少电离辐射暴露。