Suppr超能文献

开发反映东亚人群解剖特征的新型股骨柄关键特征的识别:一项形态学研究

Identification of Essential Features in Developing a Novel Femoral Stem Reflecting Anatomical Features of East Asian Population: A Morphological Study.

作者信息

Bahk Ji Hoon, Han Seung-Beom, Rhyu Kee Hyung, Yoo Jeong Joon, Lim Seung-Jae, Park Kwan Kyu, Kim Sang-Min, Lim Young Wook

机构信息

Department of Orthopedic Surgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul 14647, Republic of Korea.

Department of Orthopedic Surgery, Korea University Medical Center, College of Medicine, Korea University, Seoul 30019, Republic of Korea.

出版信息

J Clin Med. 2024 Oct 10;13(20):6030. doi: 10.3390/jcm13206030.

Abstract

: Recent advancements in hip arthroplasty aim to enhance the stability, longevity, and functionality of femoral implants. However, the distal fitting of femoral stems, often caused by metaphyseal-diaphyseal mismatch, remains a significant issue, particularly in patients with Dorr type A femora. Such mismatches can result in suboptimal implant performance, leading to potential complications. This study focuses on evaluating the anatomical compatibility of five representative single-tapered wedge mid-short stems with the mediolateral (ML) anatomy of the proximal femur in an East Asian population, where these mismatches are often more pronounced. : A total of 742 patients from two hospitals, all of whom underwent unilateral primary total hip arthroplasty, were included in the study. The contralateral proximal femur was confirmed to have normal anatomy in each patient. Hip anteroposterior radiographs were used for measurements, which were standardized in conjunction with CT images. Key anatomical parameters were measured, including proximal and distal medial-lateral canal dimensions, vertical offset, and medial offset. Five femoral stem designs-Tri-lock, Taperloc, Anthology, Accolade II, and Fit-were evaluated. R programming was employed for a detailed fit analysis to match stem sizes with patient anatomy, categorizing the fit as proximal, simultaneous proximal-distal, or distal engagement. : Among the femoral stems analyzed, the Fit stem demonstrated the closest alignment with the regression line for ML widths in the study population (slope = 0.69; population ML slope = 0.38). This was followed by Accolade II, which had a slope of 0.83. In terms of offset options, the Accolade II offered the largest offset coverage, making it particularly suitable for this population. The fit analysis revealed that the Fit stem had the highest suitable fit rate (90.56%), followed by Accolade II (73.04%). Taperloc, Anthology, and Tri-lock had similar fit rates of approximately 59%. Overall, optimal results were obtained for 92.05% of the population in the automated fitting trial, regardless of the product type. : When designing modern cementless femoral stems intended for press-fit fixation, it is crucial to account for the anatomical variations specific to the target population. In this study, Fit and Accolade II femoral components demonstrated superior compatibility with the femoral anatomy of the East Asian population, particularly in those with a higher incidence of Dorr type A femora. These stems, characterized by slimmer distal dimensions and high-offset options, appear to minimize metaphyseal-diaphyseal mismatch and associated complications.

摘要

近期髋关节置换术的进展旨在提高股骨植入物的稳定性、使用寿命和功能。然而,股骨干远端适配问题,通常由干骺端-骨干不匹配引起,仍然是一个重大问题,尤其是在多氏A型股骨患者中。这种不匹配会导致植入物性能欠佳,引发潜在并发症。本研究聚焦于评估五种具有代表性的单锥形楔形中短柄与东亚人群近端股骨内外侧(ML)解剖结构的解剖学兼容性,在该人群中这些不匹配情况往往更为明显。

该研究纳入了来自两家医院的742例患者,所有患者均接受了单侧初次全髋关节置换术。确认每位患者对侧近端股骨解剖结构正常。使用髋关节前后位X线片进行测量,并结合CT图像进行标准化。测量了关键解剖参数,包括近端和远端内外侧髓腔尺寸、垂直偏移和内侧偏移。评估了五种股骨干设计——Tri-lock、Taperloc、Anthology、Accolade II和Fit。采用R编程进行详细的适配分析,以使柄的尺寸与患者解剖结构相匹配,将适配分为近端、近端-远端同时适配或远端匹配。

在所分析的股骨干中,Fit柄在研究人群中与ML宽度的回归线显示出最接近的对齐(斜率 = 0.69;人群ML斜率 = 0.38)。其次是Accolade II,其斜率为0.83。在偏移选项方面,Accolade II提供了最大的偏移覆盖范围,使其特别适合该人群。适配分析显示,Fit柄的适配成功率最高(90.56%),其次是Accolade II(73.04%)。Taperloc、Anthology和Tri-lock的适配率相似,约为59%。总体而言,无论产品类型如何,在自动适配试验中92.05%的人群获得了最佳结果。

在设计用于压配固定的现代非骨水泥股骨干时,考虑目标人群特有的解剖变异至关重要。在本研究中,Fit和Accolade II股骨组件与东亚人群的股骨解剖结构表现出更好的兼容性,尤其是在多氏A型股骨发生率较高的人群中。这些柄的特点是远端尺寸更窄且有高偏移选项,似乎能最大程度减少干骺端-骨干不匹配及相关并发症。