Department of Removable Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt.
Department of Substitutive Dental Science, College of Dentistry, Taibah University, Saudi Arabia. Department of Removable Prosthodontics, Faculty of Dental Medicine, Al-Azhar University, Cairo, Egypt.
Braz Dent J. 2024 Oct 28;35:e245941. doi: 10.1590/0103-6440202405941. eCollection 2024.
Several impression techniques and theories have been developed for implant-retained overdentures, each with its own set of advantages and limitations. This study aimed to assess the chewing efficiency of mandibular implant-retained overdentures fabricated using three distinct impression techniques (mucofunctional, selective, and minimal pressure impression techniques). Twenty-six patients with complete edentulism free from any oral or systemic disease were selected to participate in the study. Three complete mandibular implant-retained overdentures were constructed for each patient, and grouped into three groups according to the impression technique employed in overdenture construction; Group A: Patients were treated by mandibular implant-retained overdenture fabricated using mucofunctional impression technique; Group B: Patients were treated by mandibular implant-retained overdenture fabricated using selective pressure impression technique; Group C: Patients were treated by mandibular implant-retained overdenture fabricated using minimal pressure impression technique. Chewing efficiency was evaluated for each patient with the implant-retained mandibular overdenture after three months of prosthesis insertion as an adaptation period. The data were collected, tabulated, and statistically analyzed. Results indicated that mandibular implant-retained overdentures made using the mucofunctional impression technique showed higher mean values of chewing efficiency parameters than mandibular overdentures made using selective and minimal pressure impression techniques. Within the limitations of this study, it can be concluded that the mucofunctional impression technique may be effective in improving the chewing efficiency of mandibular implant-retained overdentures more than minimal or selective pressure impression techniques.
已经开发出几种用于种植体支持式覆盖义齿的印模技术和理论,每种技术都有其自身的优点和局限性。本研究旨在评估使用三种不同印模技术(黏膜功能印模技术、选择性压力印模技术和最小压力印模技术)制作的下颌种植体支持式覆盖义齿的咀嚼效率。选择 26 名患有任何口腔或全身疾病的完全无牙患者参加本研究。为每位患者制作了三个完整的下颌种植体支持式覆盖义齿,并根据覆盖义齿制作中使用的印模技术将其分为三组;A 组:患者接受使用黏膜功能印模技术制作的下颌种植体支持式覆盖义齿治疗;B 组:患者接受使用选择性压力印模技术制作的下颌种植体支持式覆盖义齿治疗;C 组:患者接受使用最小压力印模技术制作的下颌种植体支持式覆盖义齿治疗。在适应期(即修复体插入后的三个月),使用植入式下颌覆盖义齿对每位患者的咀嚼效率进行评估。收集、制表并对数据进行统计学分析。结果表明,使用黏膜功能印模技术制作的下颌种植体支持式覆盖义齿的咀嚼效率参数的平均值高于使用选择性和最小压力印模技术制作的覆盖义齿。在本研究的限制范围内,可以得出结论,黏膜功能印模技术可能比最小或选择性压力印模技术更有效地提高下颌种植体支持式覆盖义齿的咀嚼效率。