Kissick Cameron R, Techmanski Baylee S, Comfort Paul, Suchomel Timothy J
New York Mets, Queens, New York.
Department of Human Movement Sciences, Carroll University, Waukesha, Wisconsin.
J Strength Cond Res. 2025 Mar 1;39(3):289-294. doi: 10.1519/JSC.0000000000005004. Epub 2024 Nov 5.
Kissick, CR, Techmanski, BS, Comfort, P, and Suchomel, TJ. The reliability, bias, differences, and agreement between velocity measurement devices during the hang clean pull. J Strength Cond Res 39(3): 289-294, 2025-This study examined the reliability, bias, differences, and agreement between the GymAware PowerTool (GA) and Tendo Power Analyzer (TENDO) during the hang clean pull (HCP). Fourteen resistance-trained men performed HCP repetitions with 20, 40, 60, 80, 100, 120, and 140% of their 1 repetition maximum hang power clean (1RM HPC) with GA and TENDO devices attached to the barbell. Least-products regression was used to examine instances of proportional and fixed bias for mean barbell velocity (MBV) and peak barbell velocity (PBV) between devices. In addition, Hedge's g effect sizes were calculated to determine the magnitude of the differences between devices. Excellent reliability was displayed by the GA for all measurements. While excellent reliability for the TENDO was displayed for MBV across all loads, only moderate-good reliability was present for PBV at loads >80% 1RM. The TENDO displayed proportional bias for both MBV and PBV as well as fixed bias for PBV at 140% 1RM compared with the GA. Despite the small effect sizes that existed between devices for both MBV ( g = 0.35-0.57) and PBV ( g = 0.23-0.54), none of these differences were practically meaningful. The GA and TENDO are reliable devices that can measure MBV and PBV accurately during the HCP; however, practitioners should note that the TENDO may overestimate MBV and PBV to a small extent (3.7-6.8% and 1.8-2.9%).
基西克、CR、特克曼斯基、BS、康福特、P以及苏乔梅尔、TJ。抓举提拉过程中速度测量设备之间的可靠性、偏差、差异及一致性。《力量与体能研究杂志》39(3): 289 - 294,2025年——本研究考察了抓举提拉(HCP)过程中GymAware PowerTool(GA)和Tendo Power Analyzer(TENDO)之间的可靠性、偏差、差异及一致性。14名有阻力训练经验的男性在杠铃上安装GA和TENDO设备,以其一次最大抓举力量清洁(1RM HPC)的20%、40%、60%、80%、100%、120%和140%进行HCP重复动作。采用最小乘积回归来检验设备之间杠铃平均速度(MBV)和杠铃峰值速度(PBV)的比例偏差和固定偏差情况。此外,计算了赫奇斯g效应量以确定设备之间差异的大小。GA在所有测量中均表现出出色的可靠性。虽然TENDO在所有负荷下的MBV表现出出色的可靠性,但在负荷>80% 1RM时,PBV仅表现出中等良好的可靠性。与GA相比,TENDO在140% 1RM时,MBV和PBV均表现出比例偏差,PBV还表现出固定偏差。尽管设备之间MBV(g = 0.35 - 0.57)和PBV(g = 0.2,3 - 0.54)的效应量较小,但这些差异均无实际意义。GA和TENDO是可靠的设备,能够在HCP过程中准确测量MBV和PBV;然而,从业者应注意,TENDO可能会在一定程度上高估MBV和PBV(3.7% - 6.8%和1.8% - 2.9%)。