• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Continuous versus gated pedestals and the "severe departure" from Weber's law.

作者信息

Carlyon R P, Moore B C

出版信息

J Acoust Soc Am. 1986 Feb;79(2):453-60. doi: 10.1121/1.393759.

DOI:10.1121/1.393759
PMID:3950198
Abstract

Thresholds were compared for the detection of 20-ms sinusoidal signals presented with either continuous or gated sinusoidal pedestals of the same frequency (500 or 6500 Hz). Pedestal levels ranged from 35-80 dB SPL. For 500-Hz signals, thresholds were lower in the continuous-pedestal condition than in the gated-pedestal condition, for all pedestal levels above 35 dB SPL. When the pedestal level was 35 dB, thresholds were higher in the continuous-pedestal condition than in the gated-pedestal condition. This was also true at all pedestal levels when bandstop noise centered around the pedestal frequency was added to the pedestal. For 6500-Hz signals, a deterioration in performance at intermediate levels, similar to that reported by Carlyon and Moore [J. Acoust. Soc. Am. 76, 1369-1376 (1984)], was found in the gated-pedestal condition. No such deterioration occurred in the continuous-pedestal condition. However, masking signal onsets and offsets by bursts of bandpass noise produced a midlevel deterioration in the continuous-pedestal condition. This was true when bandstop noise was absent, and when it was gated on and off in each observation interval. When continuous bandstop noise was present, no midlevel deterioration was observed, even when onsets and offsets were masked. The results suggest that in the continuous-pedestal condition subjects may normally maintain performance across level at 6500 Hz by attending to a transient response to signal onsets. Presenting bursts of bandpass noise disrupts the detection of such a response. The absence of a midlevel deterioration when continuous bandstop noise was present may be related to the adaptation to the sinusoidal pedestal that was caused by the bandstop noise.

摘要

相似文献

1
Continuous versus gated pedestals and the "severe departure" from Weber's law.
J Acoust Soc Am. 1986 Feb;79(2):453-60. doi: 10.1121/1.393759.
2
Detection of tones in noise and the "severe departure" from Weber's law.噪声中音调的检测以及与韦伯定律的“严重偏离”。
J Acoust Soc Am. 1986 Feb;79(2):461-4. doi: 10.1121/1.393533.
3
Detection of increments and decrements in sinusoids as a function of frequency, increment, and decrement duration and pedestal duration.检测正弦波中作为频率、增量、减量持续时间和基座持续时间函数的增量和减量。
J Acoust Soc Am. 1997 Nov;102(5 Pt 1):2954-65. doi: 10.1121/1.420350.
4
Intensity discrimination: a severe departure from Weber's law.强度辨别:严重偏离韦伯定律。
J Acoust Soc Am. 1984 Nov;76(5):1369-76. doi: 10.1121/1.391453.
5
The influence of external and internal noise on the detection of increments and decrements in the level of sinusoids.
Hear Res. 2001 May;155(1-2):41-53. doi: 10.1016/s0378-5955(01)00244-1.
6
Intensity resolution and loudness in high-pass noise.高通噪声中的强度分辨率与响度
J Acoust Soc Am. 1994 Apr;95(4):2171-9. doi: 10.1121/1.410017.
7
The effects of notched noise on intensity discrimination under forward masking.
J Acoust Soc Am. 1992 Oct;92(4 Pt 1):1902-10. doi: 10.1121/1.405237.
8
Intensity discrimination and increment detection in cochlear-implant users.人工耳蜗使用者的强度辨别与增量检测
J Acoust Soc Am. 2003 Jul;114(1):396-407. doi: 10.1121/1.1579007.
9
Vibrotactile intensity discrimination measured by three methods.通过三种方法测量的振动触觉强度辨别力。
J Acoust Soc Am. 1990 Jan;87(1):330-8. doi: 10.1121/1.399300.
10
Detection and intensity discrimination of a sinusoid.
J Acoust Soc Am. 1986 Nov;80(5):1335-40. doi: 10.1121/1.394385.

引用本文的文献

1
The role of the medial olivocochlear reflex in psychophysical masking and intensity resolution in humans: a review.人类中内侧橄榄耳蜗反射在心理物理掩蔽和强度分辨中的作用:综述。
J Neurophysiol. 2021 Jun 1;125(6):2279-2308. doi: 10.1152/jn.00672.2020. Epub 2021 Apr 28.
2
A new approach to sound source segregation.一种新的声源分离方法。
Adv Exp Med Biol. 2013;787:203-11. doi: 10.1007/978-1-4614-1590-9_23.
3
Relative effects of increment and pedestal duration on the detection of intensity increments.强度增量的递增和基值时长对检测的相对影响。
J Acoust Soc Am. 2011 Apr;129(4):2095-103. doi: 10.1121/1.3557043.
4
Target enhancement and noise cancellation in the identification of a rudimentary sound source in noise.在噪声中识别基本声源的目标增强和噪声消除。
J Acoust Soc Am. 2011 Feb;129(2):EL52-6. doi: 10.1121/1.3533000.
5
A method for evaluating the relation between sound source segregation and masking.一种评估声源分离与掩蔽关系的方法。
J Acoust Soc Am. 2011 Jan;129(1):EL34-8. doi: 10.1121/1.3519871.
6
Comparison of level discrimination, increment detection, and comodulation masking release in the audio- and envelope-frequency domains.音频和包络频率域中电平辨别、增量检测及共调制掩蔽释放的比较
J Acoust Soc Am. 2007 Apr;121(4):2168-81. doi: 10.1121/1.2535868.