Abstract

BACKGROUND

Viral enteric infections are illnesses caused by several types of viruses that primarily affect the gastrointestinal system. Globally, three major viruses associated with gastroenteritis, including norovirus (NoV), rotavirus A (RVA), and human adenovirus (HAdV), have been widely recognized. Accordingly, a rapid and sensitive diagnostic tool, such as immunochromatographic (IC) test, for diarrheal virus detection is required and helpful for rapid diagnosis.

METHODS

The IP-Triple I IC test kit for simultaneous triple virus detections of NoV, RVA, and HAdV was evaluated for its efficacy by using stool specimens that were known positive for these viruses by real-time RT-PCR or PCR, which was used as the gold standard method.

RESULTS

The results revealed that the IP-Triple I IC test kit exhibited a very high level of specificity (100%) for NoV, RVA, and HAdV detections, while the sensitivity was slightly different for these three viruses. The sensitivity of detection for RVA was 86.7%, whereas those for NoV and HAdV were 70.6% and 76.2%, respectively. This IP-Triple I IC kit could detect common antigens of a wide range of NoV, RVA, and HAdV genotypes (NoV GII.2, GII.4, GII.6, GII.7, GII.10, GII.17, RVA G1P[8], G2P[4], G3P[8], G8P[8], G9P[8], HAdV-C1, -C2, -C5, -A12, -F40, and -F41).

CONCLUSIONS

Our results revealed that the IP-Triple I IC test kit is highly effective for simultaneous, direct detection of common antigens of several genotypes of NoV, RVA, and HAdV in stool specimens and useful for screening and rapid diagnosis of diarrheal viruses during the seasonal outbreak.

摘要

背景

病毒性肠道感染是由几种病毒引起的疾病,主要影响胃肠道系统。在全球范围内,诺如病毒(NoV)、轮状病毒 A(RVA)和人腺病毒(HAdV)这三种与胃肠炎相关的主要病毒已被广泛认识。因此,需要一种快速灵敏的诊断工具,如免疫层析(IC)检测,用于检测腹泻病毒,这有助于快速诊断。

方法

采用实时 RT-PCR 或 PCR 检测已知为阳性的粪便标本,对同时检测 NoV、RVA 和 HAdV 的 IP-Triple I IC 试剂盒的效果进行评估,PCR 检测被用作金标准方法。

结果

结果表明,该 IP-Triple I IC 试剂盒对 NoV、RVA 和 HAdV 的检测具有非常高的特异性(100%),而对这三种病毒的检测敏感性略有不同。RVA 的检测敏感性为 86.7%,而 NoV 和 HAdV 的检测敏感性分别为 70.6%和 76.2%。该 IP-Triple I IC 试剂盒可检测到广泛的 NoV、RVA 和 HAdV 基因型(NoV GII.2、GII.4、GII.6、GII.7、GII.10、GII.17、RVA G1P[8]、G2P[4]、G3P[8]、G8P[8]、G9P[8]、HAdV-C1、-C2、-C5、-A12、-F40 和 -F41)的常见抗原。

结论

我们的结果表明,该 IP-Triple I IC 试剂盒可有效同时直接检测粪便标本中几种基因型 NoV、RVA 和 HAdV 的常见抗原,可用于筛查和季节性暴发期间的腹泻病毒快速诊断。