Ríder-Vázquez Antonio, Vega-Holm Margarita, Sánchez-González María Carmen, Gutiérrez-Sánchez Estanislao
Department of Physics of Condensed Matter Optics Area, University of Seville, Reina Mercedes S/N, 41012, Seville, Spain.
Department of Organic and Medicinal Chemistry Faculty of Pharmacy, University of Seville, 41012, Seville, Spain.
Graefes Arch Clin Exp Ophthalmol. 2025 Apr;263(4):1175-1182. doi: 10.1007/s00417-024-06684-7. Epub 2024 Nov 11.
"Minimum Perceptual Time" (MPT) is the ability to take the most visual information in the least time. The purpose of the study was to assess intraobserver and interobserver repeatability of a MPT measurement method by using COI-SV software and to analyze the possible influence of age and sex.
MPT was measured in 79 participants by using COI-SV software. Visual acuity was 20/80 (2.50 m) and numbers were gradually increasing in quantity and decreasing in exposure time. The most quantity of numbers and the least time was written down. To assess intraobserver and interobserver repeatability, a protocol based on repeating the test 4 times (2 intrasession and 2 intersessions with 2 examinators) was established. Comparison of means and Spearman correlation were performed to evaluate the influence of sex and age. It was investigated inter and intraexaminer variability using repeatability indices, as well as Bland-Altman analysis to define limits of agreement.
A total of 79 participants were included (mean age 32.8 ± 11.95 years, range 19-64 years). Regarding sex, there were no significant differences between men and women (p = 0.080), whereas age and MPT had an inverse correlation (p = 0.01). Interexaminer and intraexaminer repeatability proved to be moderate to good in all methods. Bland-Altman showed difference between sessions was 0.259 ± 2.189 (-4.030 and + 4.549) and difference between examiners was - 0.519 ± 2.104 (-4.642 and + 3.604).
MPT measurements with COI-SV software evidenced moderate to good repeatability and observers` independent result, so it could be included in optometric examinations.
WHAT IS KNOWN : Sports optometry is a relatively new field, so research is scarce and of poor quality. The scarcity of literature is practically limited to studies in the field of psychology, although they do not provide us with much information since they have not been studied for the mentioned field. The in-depth study of new standardized measurement methods would be of great help for optometrists in their clinical practice.
This study is the first to determine intraobserver and interobserver repeatability and reproducibility for Minimum Perceptual Time (MPT) measurements acquired by the COI-SV® software, exhibiting ICC > 0.7 and establishing limits of agreement by using Bland-Altman analysis. In a significant way, MPT and age would have an inverse correlation, whereas MPT results would be better in men than women. Our results add evidence towards validating the test included in COI-SV® software so that the optometrist can include it in their clinical protocols in order to obtain more complete information on visual examinations.
“最短感知时间”(MPT)是指在最短时间内获取最多视觉信息的能力。本研究的目的是通过使用COI-SV软件评估MPT测量方法在观察者内和观察者间的可重复性,并分析年龄和性别的可能影响。
使用COI-SV软件对79名参与者进行MPT测量。视力为20/80(2.50米),数字数量逐渐增加,曝光时间逐渐减少。记录下最多数量的数字和最短时间。为了评估观察者内和观察者间的可重复性,建立了一个基于重复测试4次(2次在同一时间段内,2次在不同时间段内,由2名检查者进行)的方案。进行均值比较和Spearman相关性分析以评估性别和年龄的影响。使用重复性指标研究检查者间和检查者内的变异性,并使用Bland-Altman分析来定义一致性界限。
共纳入79名参与者(平均年龄32.8±11.95岁,范围19 - 64岁)。关于性别,男性和女性之间无显著差异(p = 0.080),而年龄与MPT呈负相关(p = 0.01)。在所有方法中,检查者间和检查者内的可重复性被证明为中等至良好。Bland-Altman分析显示,不同时间段之间的差异为0.259±2.189(-4.030至+4.549),检查者之间的差异为-0.519±2.104(-4.642至+3.604)。
使用COI-SV软件进行的MPT测量显示出中等至良好的可重复性以及观察者的独立结果,因此可纳入验光检查中。
已知内容:运动验光学是一个相对较新的领域,因此研究稀缺且质量不高。文献的稀缺实际上仅限于心理学领域的研究,尽管它们没有为我们提供太多信息,因为它们尚未针对上述领域进行研究。对新的标准化测量方法进行深入研究将对验光师的临床实践有很大帮助。
本研究首次确定了通过COI-SV®软件获取的最短感知时间(MPT)测量在观察者内和观察者间的可重复性和再现性,表现出组内相关系数(ICC)> 0.7,并通过使用Bland-Altman分析建立了一致性界限。重要的是,MPT与年龄呈负相关,而MPT结果在男性中比女性更好。我们的结果为验证COI-SV®软件中包含的测试提供了证据,以便验光师可以将其纳入临床方案中,以获得更完整的视力检查信息。