Suppr超能文献

肺部吸收动力学对气溶胶粒径的依赖性。

Dependence of pulmonary absorption kinetics on aerosol particle size.

作者信息

Clark A, Byron P

出版信息

Z Erkr Atmungsorgane. 1986;166(1):13-24.

PMID:3953109
Abstract

To determine the effect of aerosol particle size upon absorption from the respiratory tract (RT), solid, polydisperse disodium fluorescein aerosols (MMDae 1.1, 3.5 and 4.4 micron) were delivered under the same respiratory regime direct to the RT of 2 Beagle dogs by positive pressure ventilation using a purpose designed administration system. Subsequent to aerosol administration the amount of fluorescein absorbed as a function of time was estimated from plasma concentration versus time and intravenous control data using a modified Loo Riegelman method. Maximum fractional deposition within the RT occurred with 3.5 micron aerosol. Fluorescein was absorbed rapidly from the RT according to an apparent first-order process the rate constant for which was independent of particle size and possibly regional deposition. Average values for absorption half lives in the 2 dogs were 17.3 and 11.4 minutes.

摘要

为确定气溶胶粒径对呼吸道(RT)吸收的影响,使用专门设计的给药系统,通过正压通气在相同呼吸模式下将固体、多分散的荧光素二钠气溶胶(空气动力学质量中值直径[MMDae]为1.1、3.5和4.4微米)直接递送至2只比格犬的呼吸道。气溶胶给药后,使用改良的Loo - Riegelman方法,根据血浆浓度与时间关系以及静脉对照数据,估算作为时间函数的荧光素吸收量。呼吸道内最大分数沉积发生在3.5微米的气溶胶中。荧光素从呼吸道以明显的一级过程快速吸收,其速率常数与粒径无关,可能与区域沉积也无关。2只犬吸收半衰期的平均值分别为17.3分钟和11.4分钟。