老化对正畸保持器拉伸强度和表面状况的影响:五种模型的比较研究。

Effects of aging on the tensile strength and surface condition of orthodontic aligners: a comparative study of five models.

作者信息

Kuntz Lucie, Aranda Lionel, Rapin Christophe, Canceill Thibault, Vande Vannet Bart, Fawaz Paul

机构信息

Department of Orthodontics, University of Lorraine, Nancy, France.

Jean-Lamour Institute, Artem Campus, University of Lorraine, Nancy, France.

出版信息

Eur J Orthod. 2024 Dec 1;46(6). doi: 10.1093/ejo/cjae063.

Abstract

BACKGROUND/OBJECTIVE: The objective of this study is to determine the effect of aging on tensile strength and surface condition of orthodontic aligners on days 0, 1, 5, 7, 10, and 14.

MATERIALS/METHODS: The total sample of 80 aligners included five brands (Accusmile®, Angel®, GRAPHY®, Invisalign® and Suresmile®) were placed in a thermocycler to imitate the temperature variations of the oral cavity and accelerate aging for 50, 250, 350, 500, and 700 cycles. The mechanical tensile properties (Young's modulus E, yield strength YS, maximum elastic stress MES, Ultimate Tensile Strength UTS, and maximum stress MS) were measured by Universal Testing Machine at a rate of 5 mm of deformation per minute for 4 minutes. Microscopic observations were made under a voltage of 10 kV at magnifications times 50, 250, 500, 1000, and 2500 after cleaning with ethanol and ultrasound then metallization with gold.

RESULTS

YS and MES of Angel® aligners are statistically reduced after five days of aging (P = .003). Aligners from the most rigid to the most flexible are (decreasing E): Accusmile® > GRAPHY® > Suresmile® > Invisalign® > Angel®. Surface conditions also deteriorated with aging (appearance of scratches, porosity, cracks, etc.). GRAPHY® aligners are more heterogeneous and weaker than others.

LIMITS

In vitro study.

CONCLUSION

Mechanical properties of Accusmile®, GRAPHY®, Invisalign®, and Suresmile® were not affected by aging. YS and MES were reduced from day 5 for Angel® aligners. Surface conditions are also altered by aging.

摘要

背景/目的:本研究旨在确定老化对正畸矫治器在第 0、1、5、7、10 和 14 天的拉伸强度和表面状况的影响。

材料/方法:总样本 80 个矫治器包括 5 个品牌(Accusmile®、Angel®、GRAPHY®、Invisalign®和 Suresmile®),将其放入热循环器中以模拟口腔温度变化并加速老化,进行 50、250、350、500 和 700 个循环。通过万能试验机以每分钟 5 毫米的变形速度在 4 分钟内测量机械拉伸性能(杨氏模量 E、屈服强度 YS、最大弹性应力 MES、极限拉伸强度 UTS 和最大应力 MS)。用乙醇和超声清洗后,在 10 kV 电压下进行微观观察,然后用金进行金属化。

结果

老化 5 天后 Angel®矫治器的 YS 和 MES 统计学上降低(P=0.003)。从最硬到最软的矫治器依次为(E 降低):Accusmile®>GRAPHY®>Suresmile®>Invisalign®>Angel®。随着老化,表面状况也恶化(出现划痕、孔隙、裂纹等)。GRAPHY®矫治器比其他矫治器更不均匀且更脆弱。

限制

体外研究。

结论

Accusmile®、GRAPHY®、Invisalign®和 Suresmile®的机械性能不受老化影响。Angel®矫治器从第 5 天开始 YS 和 MES 降低。表面状况也因老化而改变。

相似文献

2
Thermal and mechanical characterization of thermoplastic orthodontic aligners discs after molding process.
J Mech Behav Biomed Mater. 2022 Feb;126:104991. doi: 10.1016/j.jmbbm.2021.104991. Epub 2021 Nov 30.
3
Effect of in vitro aging by water immersion and thermocycling on the mechanical properties of PETG aligner material.
J Orofac Orthop. 2019 Nov;80(6):292-303. doi: 10.1007/s00056-019-00192-8. Epub 2019 Oct 2.
4
Optical properties of orthodontic aligners--spectrophotometry analysis of three types before and after aging.
Prog Orthod. 2015;16:41. doi: 10.1186/s40510-015-0111-z. Epub 2015 Nov 18.
5
Effect of oral exposure on chemical, physical, mechanical, and morphologic properties of clear orthodontic aligners.
Am J Orthod Dentofacial Orthop. 2023 Aug;164(2):e51-e63. doi: 10.1016/j.ajodo.2023.05.015. Epub 2023 Jun 17.
6
Comparison of mechanical properties of 3-dimensional printed and thermoformed orthodontic aligners.
Am J Orthod Dentofacial Orthop. 2023 May;163(5):720-728. doi: 10.1016/j.ajodo.2022.12.008.
8
In vivo aging-induced surface roughness alterations of Invisalign and 3D-printed aligners.
J Orthod. 2023 Dec;50(4):352-360. doi: 10.1177/14653125221145948. Epub 2022 Dec 27.
9
Physical, mechanical, and flexural properties of 3 orthodontic wires: an in-vitro study.
Am J Orthod Dentofacial Orthop. 2010 Nov;138(5):623-30. doi: 10.1016/j.ajodo.2009.01.032.
10
The Mechanical Properties of Orthodontic Aligners of Clear Aligner After Intraoral Use in Different Time Periods.
Orthod Craniofac Res. 2025 Apr;28(2):253-260. doi: 10.1111/ocr.12867. Epub 2024 Oct 23.

引用本文的文献

1
A systematic review of biomechanics of clear aligners by finite element analysis.
BMC Oral Health. 2025 Jul 2;25(1):1026. doi: 10.1186/s12903-025-06295-6.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验