Esteem® Active Middle Ear Implant versus Conventional Hearing Aids: Long-Term Performance.

作者信息

Barbara Maurizio, Filippi Chiara, Tarentini Silvia, Bandiera Giorgio, Monini Simonetta, Covelli Edoardo

机构信息

Otolaryngology Unit, NESMOS Department, Faculty of Medicine and Psychology, Sapienza University Hospital Sant'Andrea, Rome, Italy.

出版信息

Audiol Neurootol. 2025;30(2):146-153. doi: 10.1159/000542158. Epub 2024 Nov 19.

DOI:10.1159/000542158
PMID:39541957
Abstract

INTRODUCTION

The totally implantable active middle ear implant Esteem® may be considered an effective alternative to conventional hearing aids (cHAs) to manage moderate-to-severe forms of sensorineural hearing loss. This study aimed to provide long-term comparative data of Esteem performances with those achieved by cHA.

METHODS

From a total of 46 subjects who received unilateral application of Esteem®, and were followed up over the years, ten underwent an audiological assessment that compared the outcomes with those achieved in the contralateral ear by a cHA, considering the initially symmetric auditory thresholds in both ears. Other than pure tone audiometry and speech audiometry in quiet, the assessment was performed by using the adaptive speech in noise, i.e., Matrix test.

RESULTS

The mean speech intelligibility in quiet shows in the unaided situation a recognition of 50.7% at 71 dBHL, 71% at 69 dBHL with only contralateral cHA, 92% at 66 dBHL with only Esteem device and 94% at 61 dBHL with Esteem® device and contralateral cHA. The mean speech intelligibility in noise shows in the unaided situation a recognition of 36% at 71 dBHL, 56% at 69 dBHL with only contralateral cHA, 79% at 66 dBHL with only Esteem® device and 84% at 61 dBHL with Esteem® device and contralateral cHA. At Matrix test in the unaided condition, 4 patients reached 50% of intelligibility and the 50% threshold was obtained with a mean sound/noise ratio of +10 dBHL. In the contralaterally aided condition, 10 patients reached a 50% threshold in a condition of mean S/N ratio of +10.6 dBHL. In the Esteem® only and Esteem® plus cHA condition, all patients reached the 50% threshold with a mean S/N ratio of +3.4 dBHL with the Esteem® device and +0.92 dBHL with Esteem® plus a contralateral cHA, with a statistically nonsignificant difference. The mean deviation from the reference value (7.1 dB in the normal hearing population) was 17.1 dBHL, in unaided situation; this condition did not change with only the contralateral cHA (17.6 dBHL), whilst a significant improvement could be identified with only Esteem® device, where the mean deviation was 10.5 dBHL, and mostly with Esteem® device associated with the contralateral cHA, with a value of 8.02 dBHL.

CONCLUSIONS

The adaptive speech audiometry in noise (Matrix Test) showed that binaural stimulation provides greater benefits in the speech recognition in noise test in comparison to monaural stimulation, especially when this is carried out only by the cHA. However, the Esteem® device allowed to obtain audiological benefits that are significantly superior to those offered by cHAs, especially in cases where the hearing loss is severe and, in some cases, profound, achieving performances almost comparable to those of a cochlear implant.

摘要

相似文献

1
Esteem® Active Middle Ear Implant versus Conventional Hearing Aids: Long-Term Performance.
Audiol Neurootol. 2025;30(2):146-153. doi: 10.1159/000542158. Epub 2024 Nov 19.
2
Investigations on Directional Hearing With One-Sided Fitting of an Active Middle Ear Implant or Bone Conduction Hearing Implant.单侧植入有源中耳植入物或骨传导听力植入物的定向听力研究。
Ear Hear. 2025;46(4):1095-1110. doi: 10.1097/AUD.0000000000001650. Epub 2025 Mar 20.
3
Hearing Instruments for Unilateral Severe-to-Profound Sensorineural Hearing Loss in Adults: A Systematic Review and Meta-Analysis.成人单侧重度至极重度感音神经性听力损失的听力仪器:系统评价与荟萃分析
Ear Hear. 2016 Sep-Oct;37(5):495-507. doi: 10.1097/AUD.0000000000000313.
4
[The study on horizontal sound localization ability in patients with unilateral sensorineural hearing loss].[单侧感音神经性听力损失患者的水平声音定位能力研究]
Zhonghua Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2025 Jul 7;60(7):800-806. doi: 10.3760/cma.j.cn115330-20240719-00430.
5
Predicting Matrix Test Effectiveness for Evaluating Auditory Performance in Noise Using Pure-Tone Audiometry and Speech Recognition in Quiet in Cochlear Implant Recipients.使用纯音听力测定法和安静环境下的言语识别来预测人工耳蜗植入受者在噪声中评估听觉表现的矩阵测试有效性。
Audiol Neurootol. 2024;29(5):408-417. doi: 10.1159/000535622. Epub 2024 Apr 10.
6
Prescription of Controlled Substances: Benefits and Risks管制药品的处方:益处与风险
7
Bone Conduction Implants: Comparative of Audiometric Results and Quality-of-Life Bonebridge® versus Osia®.骨导植入物:骨桥®与 Osia®的听力学结果和生活质量比较。
Audiol Neurootol. 2024;29(5):341-350. doi: 10.1159/000537868. Epub 2024 Feb 20.
8
Parent-Reported Ease of Listening in Preschool-Aged Children With Bilateral and Unilateral Hearing Loss.家长报告的双侧和单侧听力损失学龄前儿童的听力舒适度。
Ear Hear. 2024;45(6):1600-1612. doi: 10.1097/AUD.0000000000001553. Epub 2024 Aug 9.
9
Bilateral versus unilateral hearing aids for bilateral hearing impairment in adults.成人双侧听力障碍使用双侧助听器与单侧助听器的比较。
Cochrane Database Syst Rev. 2017 Dec 19;12(12):CD012665. doi: 10.1002/14651858.CD012665.pub2.
10
Masked Speech Perception with Bone Conduction Device, Contralateral Routing of Signals Hearing Aid, and Cochlear Implant Use in Adults with Single-Sided Deafness: A Prospective Hearing Device Comparison using a Unified Testing Framework.成人单侧聋患者使用骨导助听设备、信号对侧传递助听器和人工耳蜗的掩蔽言语感知:使用统一测试框架的前瞻性听力设备比较。
Audiol Neurootol. 2024;29(4):271-289. doi: 10.1159/000535383. Epub 2024 Feb 22.