Suppr超能文献

印度人群眶下管、沟和孔的形态计量学分析:一项回顾性分析研究。

Morphometric Analysis of the Infraorbital Canal, Groove, and Foramen in the Indian Population: A Retrospective Analytical Study.

作者信息

Razak Thanzeem Noorul Amin, A C Lakshmi Rathan, Narayanan Vivek, Gurram Prashanthi

机构信息

Department of Oral and Maxillofacial Surgery, SRM Kattankulathur Dental College and Hospital, SRM Institute of Science and Technology (SRMIST), Chengalpattu, IND.

出版信息

Cureus. 2024 Oct 25;16(10):e72367. doi: 10.7759/cureus.72367. eCollection 2024 Oct.

Abstract

AIM

The aim of this research is to analyse and assess the anatomical variability of the infraorbital canal, groove, and foramen using high-resolution CT images of the Indian population using mimics software.

MATERIALS AND METHODS

A total of 100 high-resolution CT (HRCT) data (200 hemi-faces) with a range of 18-65 years in Digital Imaging and Communication in Medicine (DICOM) format was incorporated in mimics software. Infraorbital foramen (IOF), infraorbital groove (IOG), and infraorbital canal (IOC) were evaluated retrospectively using seven parameters. Statistical analysis was made, and comparisons were made with respect to gender, side, and age groups.

RESULTS

Out of 100 HRCT data obtained, 74 were of men and 13 were of women, with an average age of 32.5 years. Of 200 hemifaces, the average length of the IOC was 14.99 ± 6.25 mm, the average length of the IOG was 15.25 ± 7.87 mm, the average total length was 30.26 ± 3.36 mm, and the average transverse diameter of IOF was 2.02 ± 0.48 mm. The mean distance from IOF to the infraorbital margin (IOM) was 7.35 ± 1.67 mm, IOC to the medial wall was 16.02 ± 2.22 mm, and IOC to the lateral wall was 16.99 ± 2.47 mm.

CONCLUSION

Measurement data of infraorbital apparatus varies among different populations. This study contributes valuable knowledge regarding the measurements of the IOC, IOG, and IOF, particularly within the Indian population. This information can help by minimizing the risk of complications and improve the treatment planning for operative and anesthetic procedures.

摘要

目的

本研究旨在使用Mimics软件,通过印度人群的高分辨率CT图像,分析和评估眶下管、沟和孔的解剖变异。

材料与方法

将100份18至65岁的数字成像和通信医学(DICOM)格式的高分辨率CT(HRCT)数据(200个半侧面部)纳入Mimics软件。使用七个参数对眶下孔(IOF)、眶下沟(IOG)和眶下管(IOC)进行回顾性评估。进行了统计分析,并按性别、侧别和年龄组进行了比较。

结果

在获得的100份HRCT数据中,男性74份,女性13份,平均年龄32.5岁。在200个半侧面部中,IOC的平均长度为14.99±6.25mm,IOG的平均长度为15.25±7.87mm,总平均长度为30.26±3.36mm,IOF的平均横径为2.02±0.48mm。IOF到眶下缘(IOM)的平均距离为7.35±1.67mm,IOC到内侧壁的距离为16.02±2.22mm,IOC到外侧壁的距离为16.99±2.47mm。

结论

眶下装置的测量数据在不同人群中有所不同。本研究提供了关于IOC、IOG和IOF测量的宝贵知识,特别是在印度人群中。这些信息有助于将并发症风险降至最低,并改善手术和麻醉程序的治疗计划。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/66fb/11585966/f1e2404bd439/cureus-0016-00000072367-i01.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验