骨报告与数据系统(Bone-RADS)在计算机断层扫描上对骨肿瘤进行解读时的观察者间及观察者内一致性。

Inter-observer and intra-observer agreement of bone reporting and data system (Bone-RADS) in the interpretation of bone tumors on computed tomography.

作者信息

Ramadan Zainab Ahmad, Elmorsy Amel Helmy, Taman Saher Ebrahim, Denewar Fatmaelzahraa Abdelfattah

机构信息

Department of Radiology, Faculty of Medicine, Mansoura University, El-Mansoura 35516, Egypt.

出版信息

Clin Imaging. 2025 Jan;117:110367. doi: 10.1016/j.clinimag.2024.110367. Epub 2024 Nov 22.

Abstract

OBJECTIVE

To assess inter-observer & intra-observer agreement of the American College of Radiology (ACR) bone reporting and data system (Bone-RADS) in the interpretation of bone tumors on computed tomography (CT).

METHODS

This retrospective study included 273 bone tumors 184 (67.4 %) benign and 89 (32.6 %) malignant. Two blinded radiologists independently reviewed the CT images to assess the defined CT features of bone lesions and assign a bone-RADS category. A third observer reviewed the CT images twice with one month interval and reported the specified CT features and final bone-RADS category for bone lesions. Inter-observer and intra-observer agreement of bone-RADS were analyzed.

RESULTS

There was almost perfect inter-observer agreement between the two reviewers for all defined variables as well as bone-RADS categories (Kappa = 92.2 %). Overall intra-observer agreement was also perfect for all defined CT features and bone RADS categories with higher percentage than inter-observer one (κ = 98.3 %).

CONCLUSION

Bone-RADS is an effective clinical tool for practicing radiologists in the risk assessment and management of bone tumors with perfect agreement among observers. To our knowledge, no studies have been conducted for assessing reliability or validity of the recent ACR Bone-RADS using CT. Hence, this study could serve as a cornerstone for further upcoming studies to assess the reproducibility and validity of the ACR Bone-RADS.

摘要

目的

评估美国放射学会(ACR)骨报告与数据系统(Bone-RADS)在计算机断层扫描(CT)上对骨肿瘤进行解读时观察者间及观察者内的一致性。

方法

这项回顾性研究纳入了273例骨肿瘤,其中184例(67.4%)为良性,89例(32.6%)为恶性。两名不知情的放射科医生独立审查CT图像,以评估骨病变的既定CT特征并指定一个Bone-RADS类别。第三名观察者在间隔一个月的时间内对CT图像进行了两次审查,并报告了骨病变的特定CT特征和最终Bone-RADS类别。分析了Bone-RADS的观察者间及观察者内一致性。

结果

两位审查者在所有既定变量以及Bone-RADS类别方面的观察者间一致性几乎达到完美(kappa = 92.2%)。总体而言,观察者内对所有既定CT特征和Bone-RADS类别的一致性也达到完美,且百分比高于观察者间一致性(κ = 98.3%)。

结论

Bone-RADS是执业放射科医生在骨肿瘤风险评估和管理中的一种有效临床工具,观察者之间具有完美的一致性。据我们所知,尚未有研究使用CT评估近期ACR Bone-RADS的可靠性或有效性。因此,本研究可为进一步评估ACR Bone-RADS的可重复性和有效性的后续研究奠定基础。