Suppr超能文献

分析了元音和声音强度对嗓音声学共振峰检测结果的影响。

[The influence of vowel and sound intensity on the results of voice acoustic formant detection was analyzed].

作者信息

Xie Bing, Li Zhe, Wang Hongxing, Kuang Xuyuan, Ni Wei, Zhong Runqi, Li Yan

机构信息

Department of Rehabilitation Medicine,The First Hospital of Changsha,(The Affiliated Changsha Hospital of Xiangya School of Medicine,Central South University),Changsha,410005,China.

Department of Rehabilitation Medicine,Xiangya Hospital,Central South University.

出版信息

Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2024 Dec;38(12):1149-1153. doi: 10.13201/j.issn.2096-7993.2024.12.011.

Abstract

This study aims to explore the influence of vowels and sound intensity on formant, so as to provide reference for the selection of sound samples and vocal methods in acoustic detection. Thirty-eight healthy subjects, 19 male and 19 female, aged 19-24 years old were recruited. The formants of different vowels(/a/, //, /i/ and /u/) and different sound intensities(lowest sound, comfort sound, highest true sound and highest falsetto sound) were analyzed, and pairings were compared between groups with significant differences. ①The vowels /a/ and // in the first formant were larger than /i/ and /u/, and /i/ was the largest in the second formant. The minimum value of the first formant is the lowest sound of /i/ and the maximum is the highest sound of /a/. ②In the first formant, the chest sound area increases with the increase of sound intensity, while the second formant enters the highest falsetto and decreases significantly. Different vowels and sound intensity have different distribution of formant, that is, vowel and sound intensity have different degree of influence on formant. According to the extreme value of the first formant, the maximum normal range is determined initially, which is helpful to improve the acoustic detection.

摘要

本研究旨在探讨元音和声音强度对共振峰的影响,为声学检测中声音样本的选择和发声方法提供参考。招募了38名健康受试者,其中男性19名,女性19名,年龄在19 - 24岁之间。分析了不同元音(/a/、/ɔ/、/i/和/u/)和不同声音强度(最低音、舒适音、最高真音和最高假音)的共振峰,并对有显著差异的组间配对进行了比较。①第一共振峰中的元音/a/和/ɔ/大于/i/和/u/,/i/在第二共振峰中最大。第一共振峰的最小值是/i/的最低音,最大值是/a/的最高音。②在第一共振峰中,胸声区随声音强度的增加而增大,而第二共振峰进入最高假音时显著减小。不同的元音和声音强度有不同的共振峰分布,即元音和声音强度对共振峰有不同程度的影响。根据第一共振峰的极值初步确定最大正常范围,这有助于提高声学检测。

相似文献

8
The F1-F2 vowel chart for Czech whispered vowels a, e, i, o, u.捷克语低语元音a、e、i、o、u的F1-F2元音图表。
Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub. 2007 Dec;151(2):353-6. doi: 10.5507/bp.2007.061.
9
Level and center frequency of the singer's formant.歌手共振峰的频率水平和中心频率。
J Voice. 2001 Jun;15(2):176-86. doi: 10.1016/S0892-1997(01)00019-4.

本文引用的文献

1
2
[Acoustic elementary research on voice resonance of Chinese population].
Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi. 2010 Mar;24(6):250-2.
3
Aerodynamics of the human larynx during vocal fold vibration.声带振动时人类喉部的空气动力学
Laryngoscope. 2005 Dec;115(12):2087-100. doi: 10.1097/01.mlg.0000184324.45040.17.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验