Suppr超能文献

[Analysis of perioperative complications of flow-diverter devices in the treatment of unruptured intracranial aneurysms].

作者信息

Wang X H, Zhang R J, Tian N, Du Z H, Liu X F, Lyu B, Bian Y, Cao X Y, Wang J

机构信息

Department of Neurointervention, Department of Neurology, the First Medical Center of Chinese People's Liberation Army General Hospital, Beijing100853, China.

Department of Neurology, Zaozhuang Mining Industry Group Central Hospital, Zaozhuang277000, China.

出版信息

Zhonghua Wai Ke Za Zhi. 2024 Dec 1;62(12):1094-1103. doi: 10.3760/cma.j.cn112139-20240522-00253.

Abstract

To investigate the perioperative adverse events and complications of flow-diverter devices in the treatment of unruptured intracranial aneurysms. This is a retrospective case series study. The clinical and imaging data of 174 patients with unruptured intracranial aneurysms treated with flow-diverter devices in the Department of Neurointervention, Department of Neurology, the First Medical Center of Chinese People's Liberation Army General Hospital from January 2020 to January 2024 were retrospectively analyzed. There were 63 males and 111 females, with an age of (53.9±11.4) years (range:23 to 76 years).The occurrence, development and outcome of perioperative complications and related adverse events during treatment were collected and analyzed. The degree of aneurysm embolization was evaluated using the O'Kelly-Marotta (OKM) grading system,with OKM grade C and D as successful occlusion. A total of 187 flow-diverter devices (from 7 different brands) were implanted in 174 patients (with 294 aneurysms). Of these, 151 cases involved standalone stent embolization, 26 cases involved stent embolization combined with coil assistance, and 5 cases involved the use of two flow-diverter devices simultaneously. Twenty-nine cases (16.7%,29/174) suffered intraoperative adverse events, including 10 cases of poor stents deployment, 3 cases of stents migration into the aneurysm sac, 1 cases of abnormal guidewire movement, 4 cases of ischemic events. Complications occurred in 10 patients (5.7%, 10/174), and neurological deficits occurred in 5 patients (2.9%, 5/174). A total of 129 patients completed follow-up for more than 12 months after surgery. There were 117 aneurysms with OKM grade D and 22 with OKM grade C, showing a satisfactory healing rate of 77.7% (139/179). The effect of flow-diverter devices in the treatment of intracranial aneurysms is satisfactory, but complications and adverse events cannot be ignored, especially the relatively high incidence of perioperative adverse events, which requires neurointerventional physicians to be vigilant.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验