Neuschitzer Markus, Toledano-Serrabona Jorge, Jorba-García Adrià, Bara-Casaus J Javier, Figueiredo Rui, Valmaseda-Castellón Eduard
Department of Odontostomatology. Oral Surgery and Implantology. Faculty of Medicine and Health Sciences, Universitat de Barcelona, Barcelona, Spain.
Department of Odontostomatology. Oral Surgery and Implantology. Faculty of Medicine and Health Sciences, Universitat de Barcelona, Barcelona, Spain; Bellvitge Biomedical Research Institute (IDIBELL), Barcelona, Spain.
J Dent. 2025 Feb;153:105472. doi: 10.1016/j.jdent.2024.105472. Epub 2024 Nov 26.
To evaluate the accuracy of immediate implant placement in fresh extraction sockets in the maxillary aesthetic zone using a dynamic computer-assisted implant surgery system (dCAIS), with the evaluation of possible deviations versus freehand placement.
A total of 18 implants were placed by an experienced surgeon in fresh extraction sockets of anterior teeth in 6 maxillary models. Nine implants were placed using the dCAIS system and 9 implants were placed using the conventional freehand technique. The following outcome parameters were measured and compared: positional deviation at entry, apex point and angular deviations between planned and placed implant position. Surgery time was measured for each procedure. Descriptive and statistical analyses were performed on all outcome parameters.
Global entry deviations were not significantly different between the two techniques (p = 0.078). dCAIS resulted in significantly more accurate implant placement in terms of global apex deviation with values of 1.28±0.36 mm and angular deviations with values of 1.29±0.64°, compared to 2.06±0.60 mm and 5.05±2.54° with freehand placement (p < 0.001). The dental implant placement time was approximately three times longer when using dCAIS (10.99 ± 3.43 min) versus freehand (3.25± 0.63 min) (p < 0.001).
dCAIS achieved more precise immediate implant placement in terms of apex deviation and angulation than freehand placement, but increased the surgery time.
dCAIS provides greater accuracy in the placement of immediate implants in the maxillary aesthetic zone following prosthetic-driven digital planning compared to freehand surgery.
使用动态计算机辅助种植手术系统(dCAIS)评估在上颌美学区新鲜拔牙窝内即刻种植的准确性,并评估与徒手种植相比可能存在的偏差。
一位经验丰富的外科医生在6个上颌模型的前牙新鲜拔牙窝内植入了总共18颗种植体。9颗种植体采用dCAIS系统植入,9颗种植体采用传统徒手技术植入。测量并比较以下结果参数:入口处的位置偏差、根尖点以及计划种植位置与实际种植位置之间的角度偏差。记录每个手术过程的时间。对所有结果参数进行描述性和统计分析。
两种技术在入口处的总体偏差无显著差异(p = 0.078)。与徒手种植的2.06±0.60 mm和5.05±2.54°相比,dCAIS在总体根尖偏差方面导致种植体植入更准确,值为1.28±0.36 mm,角度偏差值为1.29±0.64°(p < 0.001)。使用dCAIS时种植体植入时间(10.99 ± 3.43分钟)比徒手种植(3.25± 0.63分钟)大约长三倍(p < 0.001)。
就根尖偏差和角度而言,dCAIS比徒手种植实现了更精确的即刻种植,但增加了手术时间。
与徒手手术相比,dCAIS在修复驱动的数字规划后,在上颌美学区即刻种植体的植入中提供了更高的准确性。