Suppr超能文献

[组织中的pH测量——动物实验中急性动脉循环障碍记录的可靠标准]

[pH measurement in tissue--a reliable criterion for the registration of acute arterial circulatory disorder in animal experiments].

作者信息

Schuster R, Appelt D, Böhme H, Häcker R, Lauschke G

出版信息

Z Exp Chir Transplant Kunstliche Organe. 1986;19(1):46-9.

PMID:3962400
Abstract

An arterial ischemia was carried out step by step in the right pelvic extremity of the dog. The ph level was measured continuously in the lateral vastus of the femoris muscle on both sides by means of a glass-one-rod measuring equipment. The pH value decreased to 6.43 ninety minutes after a total interruption of the arterial circulation. The initial value amounted to 7.20. The tissue-pH-values increase quickly during the following phase of recirculation.

摘要

在犬的右下肢进行逐步动脉缺血操作。通过玻璃单杆测量设备连续测量两侧股外侧肌的pH值。动脉循环完全中断90分钟后,pH值降至6.43。初始值为7.20。在随后的再循环阶段,组织pH值迅速升高。