• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Development of a bespoke finite element wear algorithm to investigate the effect of femoral centre of rotation on the wear evolution in total knee replacements.

作者信息

Pitt Ciaran Neil, Ashkanfar Ariyan, English Russell, Naylor Andrew, Öpöz Tahsin T, Langton David J, Joyce Thomas J

机构信息

School of Engineering, Liverpool John Moores University, Byrom Street, Liverpool, L3 3AF, UK.

School of Engineering, Liverpool John Moores University, Byrom Street, Liverpool, L3 3AF, UK.

出版信息

J Mech Behav Biomed Mater. 2025 Mar;163:106843. doi: 10.1016/j.jmbbm.2024.106843. Epub 2024 Nov 29.

DOI:10.1016/j.jmbbm.2024.106843
PMID:39647338
Abstract

Total Knee Replacements (TKRs) are a commonly used treatment to help patients suffering from severely damaged knee joints, which is normally brought on by osteoarthritis. The aim of the surgery is to reduce pain and regain function of the joint, however, some of these implants fail prematurely with implant wear being one of the main factors of failure. Computational analysis is an efficient tool that can provide an in-depth insight on the evolution of wear, before utilising experimental techniques which are time-consuming and costly. In this study, a bespoke finite element (FE) based wear algorithm has been further developed for TKRs and was used to investigate how location of femoral centre of rotation (CoR) affects the evolution of wear at the bearing surfaces. Three locations of femoral CoR have been investigated: international standards (ISO) CoR, being the location defined in ISO 14243-3, distal CoR being the centre of the femoral component's distal radius, and reference CoR being the middle ground between the two. All investigations were setup in accordance with ISO 14243-3 for displacement-controlled wear testing conditions for knee simulators. The wear algorithm extracts contact pressure and sliding distance from the FE analysis to determine wear depth, wear pattern, volumetric wear, and wear rates on the polymeric insert and femoral component's bearing surfaces using Archard's wear law. The polymeric insert volumetric wear rate after 5 million cycles (Mc) for ISO, reference, and distal CoR are 4.37mm/Mc, 5.40mm/Mc, and 6.83mm/Mc respectively. Furthermore, the wear pattern's location on the bearing surfaces is dependent on the femoral CoR, with ISO CoR wear pattern being positioned more posteriorly, distal CoR being more anteriorly, and reference CoR in between ISO and distal. The ISO CoR investigation showed a region of minimal wear between two wear regions at the middle of the femoral component's wear pattern, on both medial and lateral condyles. This region of minimal wear reduces for the reference CoR and further reduces for the distal CoR. After 5 Mc, the average polymeric insert-femoral component contact area changes with femoral CoR, with the average contact area being 66.53mm, 68.35mm, and 71.21mm for ISO, reference, and distal CoRs respectively, with distal having around 7% more contact area than ISO. The results from this study show that there is a wide range of wear values for different locations of femoral CoR. As such the choice of femoral CoR should be carefully considered when performing any wear investigation to ensure that the CoR location is consistent for all studies being compared.

摘要

相似文献

1
Development of a bespoke finite element wear algorithm to investigate the effect of femoral centre of rotation on the wear evolution in total knee replacements.
J Mech Behav Biomed Mater. 2025 Mar;163:106843. doi: 10.1016/j.jmbbm.2024.106843. Epub 2024 Nov 29.
2
The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3.股骨旋转中心的选择会影响全膝关节置换磨损测试中的材料损失——ISO 14243-3 的参数有限元研究。
J Biomech. 2019 May 9;88:104-112. doi: 10.1016/j.jbiomech.2019.03.027. Epub 2019 Mar 23.
3
Comparison of ISO 14243-1 to ASTM F3141 in terms of wearing of knee prostheses.就膝关节假体磨损情况而言,ISO 14243-1与ASTM F3141的比较。
Clin Biomech (Bristol). 2019 Mar;63:34-40. doi: 10.1016/j.clinbiomech.2019.02.008. Epub 2019 Feb 15.
4
Understanding the differences in wear testing method standards for total knee replacement.了解全膝关节置换磨损测试方法标准的差异。
J Mech Behav Biomed Mater. 2022 Aug;132:105258. doi: 10.1016/j.jmbbm.2022.105258. Epub 2022 May 8.
5
Cementless, Cruciate-Retaining Primary Total Knee Arthroplasty Using Conventional Instrumentation: Technical Pearls and Intraoperative Considerations.使用传统器械的非骨水泥型、保留交叉韧带初次全膝关节置换术:技术要点与术中注意事项
JBJS Essent Surg Tech. 2024 Sep 13;14(3). doi: 10.2106/JBJS.ST.23.00036. eCollection 2024 Jul-Sep.
6
Enhanced In-Silico Polyethylene Wear Simulation of Total Knee Replacements During Daily Activities.日常活动期间全膝关节置换术中增强的计算机模拟聚乙烯磨损情况
Ann Biomed Eng. 2021 Jan;49(1):322-333. doi: 10.1007/s10439-020-02555-4. Epub 2020 Jun 30.
7
Experimental and computational evaluation of knee implant wear and creep under in vivo and ISO boundary conditions.在体内和ISO边界条件下膝关节植入物磨损和蠕变的实验与计算评估
Biomed Eng Online. 2024 Dec 23;23(1):130. doi: 10.1186/s12938-024-01321-0.
8
Finite element evaluation of the newest ISO testing standard for polyethylene total knee replacement liners.聚乙烯全膝关节置换衬垫最新ISO测试标准的有限元评估
Proc Inst Mech Eng H. 2018 Jun;232(6):545-552. doi: 10.1177/0954411918770700. Epub 2018 Apr 15.
9
Mobile medial pivot (lateral slide)-type total knee arthroplasty exhibited different motion patterns between under anaesthesia and weight-bearing condition.在麻醉和负重状态下,移动中轴(外侧滑动)型全膝关节置换表现出不同的运动模式。
Knee Surg Sports Traumatol Arthrosc. 2024 May;32(5):1298-1307. doi: 10.1002/ksa.12147. Epub 2024 Mar 19.
10
Biomechanical comparison of fixed- and mobile-bearing for unicomparmental knee arthroplasty using finite element analysis.采用有限元分析对单髁膝关节置换术中固定和活动平台假体的生物力学进行比较。
J Orthop Res. 2014 Feb;32(2):338-45. doi: 10.1002/jor.22499. Epub 2013 Oct 10.

引用本文的文献

1
Computational Study of Stress Distribution in Polyethylene Elements Due to Metal Components of Knee and Hip Implants Made from Different Metal Alloys.不同金属合金制成的膝关节和髋关节植入物金属部件对聚乙烯部件应力分布的计算研究
Materials (Basel). 2025 Aug 21;18(16):3924. doi: 10.3390/ma18163924.