Pisano Massimo, Iandolo Alfredo, Abdellatif Dina, Chiacchio Andrea, Galdi Marzio, Martina Stefano
Department of Medicine, Surgery and Dentistry 'Scuola Medica Salernitana', University of Salerno, Baronissi, Italy.
Restor Dent Endod. 2024 Sep 5;49(4):e33. doi: 10.5395/rde.2024.49.e33. eCollection 2024 Nov.
The aim of this study was to compare the effects of different polymerization strategies and the effectiveness of finishing and polishing procedures of composite resins on color stability.
The samples were divided into 4 main groups according to the polymerization strategy, and all groups except the control group received surface treatment. Each group was subsequently divided into 3 subgroups respectively: Kuraray Clearfil Majesty ES-2 Classic, Premium and Universal. Approximately 24 hours after preparation of the samples, they were immersed for 7 days in a coffee solution. A first color measurement was performed after the preparation of the samples, the second measurement was performed after 7 days in the coffee solution. All measurements were carried out using a dental spectrophotometer to assess the CIE * * * color parameters.
There was a statistically significant difference between ΔE values for different procedures ( = 0.003); in particular, the differences were found only between the groups that received surface treatment and the control group. In addition, a statistically significant difference was observed between the values of ΔE for different composites in the different procedure groups.
Spectrophotometric analysis showed that the additional photopolymerization and oxygen inhibition procedures did not yield better results in relation to color stability. In addition, finishing and polishing provided better color stability compared to not performing these procedures.
本研究旨在比较不同聚合策略的效果以及复合树脂的修整和抛光程序对颜色稳定性的影响。
根据聚合策略将样本分为4个主要组,除对照组外的所有组均接受表面处理。随后每组再分别分为3个子组:可乐丽Clearfil Majesty ES-2经典型、高级型和通用型。样本制备后约24小时,将其浸泡在咖啡溶液中7天。在样本制备后进行第一次颜色测量,在咖啡溶液中浸泡7天后进行第二次测量。所有测量均使用牙科分光光度计进行,以评估CIE *** 颜色参数。
不同程序的ΔE值之间存在统计学显著差异(=0.003);特别是,仅在接受表面处理的组与对照组之间发现差异。此外,在不同程序组中,不同复合材料的ΔE值之间观察到统计学显著差异。
分光光度分析表明,额外的光聚合和氧抑制程序在颜色稳定性方面并未产生更好的结果。此外,与不进行这些程序相比,修整和抛光提供了更好的颜色稳定性。